background image

Troubleshooting

What is it doing?

Possible causes

Check and correct

Nothing. No audio, and the
power light does not illuminate.

Power is not connected.

Connect the power supply.

The power outlet is not
supplying power.

Check to see whether the outlet powers
other devices, such as a phone
charger.

The power supply is bad.

Call Vaddio technical support.

The microphone is on, but no
audio is available from the
corresponding line out.

The cable from the
microphone or the
microphone interface box is
not connected, or is bad.

Verify that the cable is connected to the
device.

Check the cable for correct pin-out and
continuity.

Echo or feedback.

Speaker audio needs to be
echo-canceled.

Connect the appropriate mixer output
to the AEC reference connector.

Use, Storage, and Care

Keep this device away from food and liquids. Do not attempt to take this product apart. There are no
user-serviceable components inside. Do not operate or store the device under any of the following
conditions:

n

Temperatures above 104° F (40° C) or below 32° F (0°C)

n

High humidity, condensing or wet environments

n

Inclement weather

n

Severe vibration

n

20,000 leagues under the sea

n

Dry environments with an excess of static discharge

Vaddio is a brand of Legrand AV Inc.·

www.legrandav.com

· Phone 800.572.2011 / +1.763.971.4400 ·

Fax +1.763.971.4464 · Email

[email protected]

·

Vaddio is a registered trademark of Legrand AV Inc. All other brand names or marks are used for
identification purposes and are trademarks of their respective owners. All patents are protected under
existing designations. Other patents pending.

©2021 Legrand AV Inc.

Installation Guide for the EasyUSB MicPOD I/O Microphone Interface

Summary of Contents for VADDIO EasyUSB MicPOD I/O

Page 1: ...n 999 8535 009 Australia New Zealand About this Manual Information in this manual includes n Physical features n Installation n Troubleshooting Features The EasyUSB MicPOD I O interfaces up to four Vaddio EasyMic conference room microphones into a non EasyMic environment such as a professional mixer n Connections for four EasyMic conference room microphones n Four balanced line outputs n Connectio...

Page 2: ...appen return it to Vaddio for safety and functional testing Cabling Notes Caution Do not use pass through RJ 45 connectors when making cables for this product Poorly crimped connectors of this type can cause intermittent connections and degraded signal quality They can also damage the connectors on the product which will void your warranty Intact will make reliable contact with cable connector Dam...

Page 3: ...o during a conference When it sends the far end audio back to the participants at the far end it creates an echo The same thing can happen in a non conferencing environment too Acoustic echo cancellation prevents this Here s how it works 1 The speaker feeds audio into the room This signal also goes to the audio processor as the reference that needs to be canceled 2 The audio processor inverts the ...

Page 4: ... and Physical Operating Storage Temperature 32 F to 104 F 0 C to 40 C Operating Storage Humidity 10 to 80 non condensing Maximum Cabling Distance 100 ft 30 m Maximum Power Consumption 40 W Dimensions Width 8 38 in 21 27 cm Depth 6 0 in 15 24 cm Height 1 72 in 4 37 cm Weight 1 4 lbs 0 6 kg Installation Guide for the EasyUSB MicPOD I O Microphone Interface 4 ...

Page 5: ...onnector Use Storage and Care Keep this device away from food and liquids Do not attempt to take this product apart There are no user serviceable components inside Do not operate or store the device under any of the following conditions n Temperatures above 104 F 40 C or below 32 F 0 C n High humidity condensing or wet environments n Inclement weather n Severe vibration n 20 000 leagues under the ...

Reviews: