Doc No. FM0465 issue E Page 1
ZXT444 D
OOR
C
O
N
T
A
C
T
F
req.
169.4
81
25
M
H
z
Envir
onme
nta
l G
rou
p I
I
Ma
de
in
U
K
tyn
ete
c
We declare this product complies with the relevant UK
legislation on condition that it is used in the manner
intended, and in accordance with the current installation
standards and/or the manufacturer's recommendations.
A copy of the full UKCA Declaration of Conformity is
available on request.
169MHz Telecare Devices
Alarm Door Contact
__________________________________________________________________________________________________________
•
Compatible with Reach at-home alarms,
Advent xt warden call and Altec Response carer alarms
•
Self-adhesive contact & transmitter unit
•
Supplied with surface mount door magnet
•
Low battery warning
•
Dimensions: 80mm x 40mm x 20mm (HxWxD)
•
Weight: 49 grams
•
Product Code: ZXT434
What is the Alarm Door Contact used for?
The alarm door contact is used to raise a door exit (client wandering) alarm every time a door is opened.
Note: there is no facility to override the alarm.
Where should the Alarm Door Contact be fitted?
The magnet will usually be screw fixed to the door with the transmitter unit fixed alongside as close as possible on the door frame
using the self adhesive foam pad. These parts can be reversed if it is more convenient to fit.
Fitting the Alarm Door Contact
The transmitter unit and a magnet will be held together with an
elastic band to prevent the battery being drained in transit.
Remove the elastic band and fix the transmitter unit to the
door frame using the self adhesive foam pad provided.
Fix the magnet to the door
alongside the “
CONTACT SIDE
”
label
on the transmitter unit using the screws provided.
Note: there should be no more than 10mm gap between the
transmitter unit and the magnet when the door is closed.
When the door is opened the magnet must move away
from the transmitter unit.
Testing & Registering the Alarm Door Contact
A test call is necessary to learn the door contact onto the Reach at-home alarm, Advent xt warden call or Altec Response local
carer alarm. See the following pages for how to put each of
these
products
into “Learn Mode”.
To perform a test call simply open and close the door.
The range of all radio devices can be affected by the working environment - always take care during installation and
perform several test calls.
Battery Life
The transmitter battery is checked once a day, if the voltage falls and stays below a preset level for 7 consecutive days a low
battery alert is automatically transmitted. Once a low battery call is received the door contact should be replaced within 7 days.
Door Contacts must be returned to Tynetec/Aidcall for battery replacement.
Detailed information on battery management for all Tynetec/Aidcall products is available - request Doc No. FM0630.
WARNING:
If the door is left open for an extended period this will cause unnecessary drain on the battery and
may reduce its life considerably.
Declaration of Conformity
DOOR FRAME
DOOR
MAGNET
TRANSMITTER UNIT
Tynetec and Aidcall are business units of Legrand Electric Ltd
Unit 10 Cowley Road, Blyth Riverside Business Park, Blyth
Northumberland, NE24 5TF. Tel:
01670 352 371
Email:
Web
:
www.tynetec.co.uk
We declare this product complies with the relevant
European legislation on condition that it is used in the
manner intended, and in accordance with the current
installation standards and/or the manufacturer's
recommendations. A copy of the full CE Declaration of
Conformity is available on request.