background image

2 / 5 

 

Thermal relays RTX

Thermal relays RTX

Thermal relays RTX

Thermal relays RTX    

 

Cat N°(s)

Cat N°(s)

Cat N°(s)

Cat N°(s)    : : : : 0 

0 294 58/59/60/61/62/63/64/65/66/67/68/69/70/71/72/ 

294 58/59/60/61/62/63/64/65/66/67/68/69/70/71/72/ 

294 58/59/60/61/62/63/64/65/66/67/68/69/70/71/72/ 

294 58/59/60/61/62/63/64/65/66/67/68/69/70/71/72/ 

73/74/7

73/74/7

73/74/7

73/74/75/76/77/78/82/83/84/85/86/87/88                                             

5/76/77/78/82/83/84/85/86/87/88                                             

5/76/77/78/82/83/84/85/86/87/88                                             

5/76/77/78/82/83/84/85/86/87/88                                             

0 294 94/95

294 94/95

294 94/95

294 94/95

    

 

 

 

5. OVERALL DIMENSIONS

5. OVERALL DIMENSIONS

5. OVERALL DIMENSIONS

5. OVERALL DIMENSIONS    

(Continued)

 

RTX-2, Cat N° 0 294 82 up to 0 294 85 : 

    

RTX-2, Cat N° 0 294 86 up to 0 294 88 : 

    

6666. . . . ELECTRICAL CHARACTERISTICS

ELECTRICAL CHARACTERISTICS

ELECTRICAL CHARACTERISTICS

ELECTRICAL CHARACTERISTICS    

  

  

RTX-1  

0 294 58 up 

to 0 294 71 

RTX-1 

0 294 72 up 

to 0 294 78 

RTX-2 

0 294 82 up to 

0 294 85 

RTX-2 

0 294 86 up to  

0 294 88 

Class 

  

10A 

10 

10 

10 

Setting range (A)  

  

0,65 ... 40  

24 ... 110  

63 ... 190  

120 ... 310  

Suitable for 

  

CTX-1 

9A up to 40A 

CTX-1 

50A up to 105A 

CTX-2 

150A up to 185A 

CTX-2 

250A up to 310A 

Power circuit 

Rated insulation voltage Ui (IEC947-4) 

(V) 

690 

1000 

1000 

1000 

Frequency limits  

(Hz) 

0...400  

0...400  

0...400  

50...60  

Wiring capacity 

  

 

Clamp terminal – rigid conductor 

(mm2) 

50 

120 

Clamp terminal – flexible conductor 

(mm2) 

35 

120 

With flat terminal 

(mm) 

25 x 5 

Passing by hole - bar 

(mm) 

30 x 10 

Tightening torque 

(Nm) 

2,5 

4,5 

6,5 

23 

Control circuit 

Rated insulation voltage Ui (IEC60947-4)  

(V) 

690 

Conventional thermal current Ith 

(A) 

10 

Rated voltage / Rated current 

  

  

AC-15 - Ue-Ie 

(V - A) 

110/120 - 3 ; 220/240 - 2 ; 380/415 - 1 ; 

 480/500 - 0,8 ; 660/690 - 0,3 

DC-13 - Ue-Ie 

(V - A) 

24 - 2 ; 48 - 1,4 ; 110 - 0,6 ; 250 - 0,3 ; 440 - 0,1 

Utilization according Ul and CSA 

  

B600 Q600 

gL type fuse 

(A) 

10 

Wiring capacity 

(mm2) 

2,5 

Tightening torque 

(Nm) 

0,8 

Operating conditions 

Storage temperature 

  

-40ºC à +70ºC 

Ambiant operating temperature 

  

-25ºC a +60ºC 

Operating altitude 

  

Up to 3000m without derating 

Humidity 

  

98% 

Protective treatment 

  

Tropicalized 

 

    

 

 
 

 

 
 

 

 
 

 

 
 

 

 
 

 

  Technical data sheet: F01169EN/00 

Updated on: / 

Created on: 13/12/2012 

 

 

Summary of Contents for RTX Series

Page 1: ...9A up to 40A 2 5A 4A 0 294 63 For CTX 1 from 9A up to 40A 4A 6 3A 0 294 64 For CTX 1 from 9A up to 40A 5 5A 8 5A 0 294 65 For CTX 1 from 9A up to 40A 8A 12A 0 294 66 For CTX 1 from 9A up to 40A 10A 16A 0 294 67 For CTX 1 from 9A up to 40A 14 5A 18A 0 294 68 For CTX 1 from 9A up to 40A 17 5A 22A 0 294 69 For CTX 1 from 9A up to 40A 21A 26A 0 294 70 For CTX 1 from 9A up to 40A 25A 32A 0 294 71 For C...

Page 2: ... up to 0 294 88 Class 10A 10 10 10 Setting range A 0 65 40 24 110 63 190 120 310 Suitable for CTX 1 9A up to 40A CTX 1 50A up to 105A CTX 2 150A up to 185A CTX 2 250A up to 310A Power circuit Rated insulation voltage Ui IEC947 4 V 690 1000 1000 1000 Frequency limits Hz 0 400 0 400 0 400 50 60 Wiring capacity Clamp terminal rigid conductor mm2 6 50 120 Clamp terminal flexible conductor mm2 4 35 120...

Page 3: ...7 TRIPPING CURVES RTX 1 reference 0 294 58 up to 0 294 71 class 10A RTX 1 reference 0 294 72 up to 0 294 78 class 10 RTX 2 reference 0 294 82 up to 0 294 85 class 10 RTX 2 reference 0 294 86 up to 0 294 88 class 10 Technical data sheet F01169EN 00 Updated on Created on 13 12 2012 Multiple of setting current One phase Cold condition Three phases Cold condition Three phases Heat condition Tripping t...

Page 4: ...TEST TEST TEST TEST Fonction Fonction Fonction Fonction When the test button is pressed the status of auxiliary contacts change 8 2 8 2 8 2 8 2 Operation in manual reset Operation in manual reset Operation in manual reset Operation in manual reset The thermal relay must be reset by pressing the test button in order to restart the load 8 3 8 3 8 3 8 3 Operation in manual reset and stop Operation in...

Page 5: ...88 0 0 0 0 294 94 95 294 94 95 294 94 95 294 94 95 8 4 Operation in automatic reset with stop 8 4 Operation in automatic reset with stop 8 4 Operation in automatic reset with stop 8 4 Operation in automatic reset with stop The thermal relay is automatically reset after the cooling of bi metal A pushing on the test button is used to stop the load 8 5 8 5 8 5 8 5 Operation in automatic reset with Op...

Reviews: