background image

Visit our website for FAQs: www.passandseymour-.com

OPERATION

The dimmer may feel warm to the touch during normal operation.

Replacing Lamps

When a lamp must be replaced, use the Air Gap Isolation feature for safety. To

activate the feature:

Press

FIRMLY, so that the paddle clicks and

latches in

.

Make sure the status LED is extinguished, indicating that it’s safe to relamp.

To release and return to normal operation, press

. The status LED lights.

Power Fail Memory

After a power failure, all LightSense™ devices automatically return to the state

that they were in immediately prior to loss of power. All configuration and scene

control information is preserved.

When you see

in the

instructions,

touch the top

of the paddle

as directed.

When you see

in the

instructions,

touch the

bottom of the

paddle as

directed.

Tap once

Fade the load to its last-used level

Tap twice

Full bright

– –

Press and hold

Increase the present level

Tap once

Fade the load to OFF

– –

Press and hold

Decrease the present level

Summary of Contents for Pass & Seymour LightSense PSWDI

Page 1: ...erating Voltage 120VAC 60Hz Maximum Load Rating 600W Minimum Load Required 60W Load Type Compatibility 60 600W Incandescent tungsten quartz halogen transformers U S Patent 6 175 220 Other utility desi...

Page 2: ...and compact fluorescent fixtures electronic low voltage neon or cold cathode fixtures or diode equipped lamps use the LightSense PSWDU wireless universal dimmer or the LightSense PSHDU universal dimm...

Page 3: ...LOAD and GND supply wires to the correspondingly marked screw terminals according to one of the wiring diagrams below 5 If NEUTRAL wires are provided to the fixture connect them together using a wire...

Page 4: ...2 seconds All device LEDs in the house change to solid green indicating house binding is complete Adding a Device to an Existing Installation If you re adding or replacing a device in a LightSense wir...

Page 5: ...to normal operation press The status LED lights Power Fail Memory After a power failure all LightSense devices automatically return to the state that they were in immediately prior to loss of power Al...

Page 6: ...flashing LED Included in the Group Green flashing LED NOT included in the Group If you get to a device and it is NOT flashing the 5 minute binding process timer may have expired Go back to step 1 and...