background image

 

 
 
 
 
 
 
301 Fulling Mill Road, Suite G 
Middletown, PA 17057 
Phone (800) 321-2343 / Fax (717) 702-2546 
www.onqlegrand.com

 

 

 

 

 

 

 

 

 

 

 

 

 

                  

 

 

Page 2 of 8

 

INSTRUCTION/INSTALLATION SHEET 
lyriQ™ Standard Keypad

 

IS-0391 REV. E

 

  ©Copyright 2009 by Legrand All Rights Reserved. 

 

 

 

A. “Rough-in” 

steps: 

 

1)  A single Category 5 cable should be run from the enclosure location to a single gang outlet box or mud 

ring at each Volume Control location. 

 
NOTE: We also recommend running a 16/4 speaker wire along with the Category 5 cable to support 
future upgrades to High Performance Keypads if desired. 

 

 

B. “Trim-out” 

steps: 

 
1)  Connect the volume control by terminating the pre-wired Category 5 cable from the enclosure with an 

RJ45 plug, following the T568A wiring standard and insert this plug into jack J1 (see

 

Figure 2

)

 
2)  For the Line Out/Speakers Out connections (TB1/TB2) strip 3/8” of insulation from each of the four 

conductors and insert the appropriate wires into the appropriate connections (see

 

Figure 2

)

.   

 

NOTE: Polarity and channels are clearly marked (L+, L-, R-, R+) for proper identification during 
installation. 

 

 

a)   Use TB2 to connect one pair (only) of 8 ohm ev

ō

Q™ audio speakers to the volume control. 

 

b)   Use TB1 to connect your ev

ō

Q™ powered sub-woofer or an external amplifier to the volume control. 

These connection terminals do not provide any amplification but the volume control on the keypad 
controls the output level of this connection. 

 
3)  Connections in the enclosure (see

 

Figure 3

): 

 
a)   The Category 5 cable that was run to each volume control location should be terminated with an RJ45 

plug according to the T568A wiring standard and inserted into one of the zone output jacks of the 
associated lyriQ™ audio distribution module. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 3 

Summary of Contents for lyriQ

Page 1: ...EDs SOURCE with four green Source Selection LEDs and MUTE with one red status LED There is also an IR target window and tri colored status LED The rear of the lyriQ Standard Keypad see Figure 2 contai...

Page 2: ...jack J1 see Figure 2 2 For the Line Out Speakers Out connections TB1 TB2 strip 3 8 of insulation from each of the four conductors and insert the appropriate wires into the appropriate connections see...

Page 3: ...e 8 Zone Module cascade Single Source Modules To cascade a Single Source Module simply run a Category 5 jumper from the Cascade Out RJ45 jack on the front panel of the first Module to the Source In RJ...

Page 4: ...wait for 10 second time out see Figure 5 NOTE When any Keypad button is tapped back light level goes to full bright and returns to the adjusted level when activity ceases For Remote operation the back...

Page 5: ...nd then 2 and finally to 3 while double tapping it will cause every active keypad to go directly to Source 3 NOTE The Whole House Source Control mode will be exited when the user fails to press a key...

Page 6: ...controlled from other keypads on the system that have engaged Whole House Mode Whole House Disable src 1 vol 2 turns off the ability of a keypad to be controlled by other keypads that have engaged Who...

Page 7: ...of radiated interference IR Target Disabled for use when system is installed in environments that have extreme levels of radiated interference Nightlight Default src 1 3 vol 1 Keypad glows dimly when...

Page 8: ...al source which requires a change Auto Off Enable Disable Default src 2 4 vol 1 Keypad will turn off after 20 minutes of no music Auto Off Disable src 2 4 vol 2 Keypad will remain on until manually tu...

Reviews: