LEGRAND LEGD365 061 Installation Instructions Manual Download Page 8

CENTURION

THE AUTOMATIC CHOICE

 CENTURION SYSTEMS (PTY) LTD HEAD OFFICE:

TEL: +27 (0)11 699-2400, FAX: +27 (0)11 704-3412 or 462-6669

 148 EPSOM AVENUE, NORTH RIDING

P.O. BOX 506, CRAMERVIEW, 2060

SOUTH AFRICA

WEB: http://www.centsys.co.za     General information e-mail: [email protected]  Sharecall Number: 0860-CENTURION

FOR TECHNICAL SUPPORT CONTACT:

JOHANNESBURG CENTRAL/WR . . . . . . . . . . (011) 699-2400
JOHANNESBURG  EAST-RAND . . . . . . . . . . . (011) 397-6401
PRETORIA. . . . . . . . . . . . . . . . . . . . . . . . (012)  362-8819/8893
VEREENIGING . . . . . . . . . . . . . . . . . . . . . . . . . (016)  422-5667
NELSPRUIT. . . . . . . . . . . . . . . . . . . . . . . . . . (013)  752-8074/5
DURBAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 031)  701-9583
KIMBERLEY . . . . . . . . . . . . . . . . . . . . . . . . . . . (053)  832-3231
BLOEMFONTEIN . . . . . . . . . . . . . . . . . . . . . . . (051)  448-1714
CAPE  TOWN . . . . . . . . . . . . . . . . . . . . . . . . . . (021)  447-1295
PORT ELIZABETH . . . . . . . . . . . . . . . . . . . . (041) 581-6994/5
EAST  LONDON . . . . . . . . . . . . . . . . . . . . . . . . (043)  743-4923
GEORGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (044)  874-6965
WINDHOEK . . . . . . . . . . . . . . . . . . . . . . . . (09264)  6-1220830
HARARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . (092)  634795-873
GABARONE. . . . . . . . . . . . . . . . . . . . . . . . . . . (09267)  351194

10

54

.D

.0

1.

00

03

_1

Le

gr

an

In

sta

lla

tio

Bo

ok

le

t S

er

ie

s 7

Summary of Contents for LEGD365 061

Page 1: ...mmunication between the handset and entry panel can take place If at the same time any other handset is lifted off its cradle there will be common communication with the first handset and the entry pa...

Page 2: ...ERNATIVELY Table of recommended cross sections 2 4 n 5 2 5 5 5 4 n 2 4 n 4 OR 12V DC Power Supply only Door strike or Gate release CP13E 12V Power supply NOTES 1 A door strike can only be connected di...

Page 3: ...onnected directly to the entry panel as shown if an AC supply is powering the unit NOTE 4 p1 p2 pn are the call lines to the handset s in each apartment house With an apartment system each apartment w...

Page 4: ...lock and the power supply is 12V DC NOTE 1 Select the chime type in the sound unit Left jumper electronic NOTE 2 p1 p2 pn are the call lines to the handset s in each apartment house With an apartment...

Page 5: ...cessory Connection of an electric rim lock to entry panel using an AC power supply only 2 3 4 5 1E P P 1Z 2 3 4 5 1E P P 1Z Series 7 entry panel Series 7 Series 7 Series 7 entry panel 11 CP76 Relay Re...

Page 6: ...n backing piece from the facia Insert the label and replace the plastic backing piece 11 Clip the module back onto the facia 15 Hinge open the entry panel and terminate the wiring referring to the wir...

Page 7: ...k Larsen effect The lock must be powered Check in the entry panel that Adjust the volume in the entry panel 4 None of the handsets sound reaches the entry panel the voltage is approx 12 V AC between t...

Page 8: ...860 CENTURION FOR TECHNICAL SUPPORT CONTACT JOHANNESBURG CENTRAL WR 011 699 2400 JOHANNESBURG EAST RAND 011 397 6401 PRETORIA 012 362 8819 8893 VEREENIGING 016 422 5667 NELSPRUIT 013 752 8074 5 DURBAN...

Reviews: