LEGRAND LEGD365 061 Installation Instructions Manual Download Page 1

Installation instructions for entry kits using entry panels
LEGD365 061/062/064/066/068/069/060

Description

Components required for 1 to multi apartment kits

Entry Panel
(Made up in 2 button increments
to suit number of call buttons required)

1

6

5

0

Ground

1

6

0

0

85

2

1

9

Ground

Series 7 Handset

Surface Box
mild steel or
3CR12 stainless steel
with light grey epoxy coating
(Select size according to
configuration of entry panel)

Power supply unit
CP13E/12V

alternatively connect to
12V DC battery of gate motor

System operation

When a call button on the outside entry panel is pressed all the handsets connected to this call button will ring. A 
maximum of four handsets can be connected to one call button. There will be a simultaneous ring at the entry panel to 
confirm the ringing at the handset(s). When lifting the handset off its cradle inside, communication between the 
handset and entry panel can take place. If at the same time   any other handset is lifted off its cradle, there will be 
common communication with the first handset and the entry panel. At any time any handset in the system can be lifted 
off its cradle and there will be a communication link with the entry panel. This is regardless of whether this handset has 
been called from the entry panel. The speech volume at the handset(s) and entry panel can be set independently. 
The entrance door or gate can be operated using the door/gate release pushbutton provided on the handset. A second 
pushbutton is provided to operate auxiliary functions such as other features on the entrance gate operator or switch a 
light outside the front door or gate. A pushbutton is provided on the entry panel to illuminate the call button label and 
improve usability in dark conditions. This latest generation of entry panels, the Series 7, simplifies the installation of the 
system, and through improved weatherproofing enhances the long term reliability of the product.

Summary of Contents for LEGD365 061

Page 1: ...mmunication between the handset and entry panel can take place If at the same time any other handset is lifted off its cradle there will be common communication with the first handset and the entry pa...

Page 2: ...ERNATIVELY Table of recommended cross sections 2 4 n 5 2 5 5 5 4 n 2 4 n 4 OR 12V DC Power Supply only Door strike or Gate release CP13E 12V Power supply NOTES 1 A door strike can only be connected di...

Page 3: ...onnected directly to the entry panel as shown if an AC supply is powering the unit NOTE 4 p1 p2 pn are the call lines to the handset s in each apartment house With an apartment system each apartment w...

Page 4: ...lock and the power supply is 12V DC NOTE 1 Select the chime type in the sound unit Left jumper electronic NOTE 2 p1 p2 pn are the call lines to the handset s in each apartment house With an apartment...

Page 5: ...cessory Connection of an electric rim lock to entry panel using an AC power supply only 2 3 4 5 1E P P 1Z 2 3 4 5 1E P P 1Z Series 7 entry panel Series 7 Series 7 Series 7 entry panel 11 CP76 Relay Re...

Page 6: ...n backing piece from the facia Insert the label and replace the plastic backing piece 11 Clip the module back onto the facia 15 Hinge open the entry panel and terminate the wiring referring to the wir...

Page 7: ...k Larsen effect The lock must be powered Check in the entry panel that Adjust the volume in the entry panel 4 None of the handsets sound reaches the entry panel the voltage is approx 12 V AC between t...

Page 8: ...860 CENTURION FOR TECHNICAL SUPPORT CONTACT JOHANNESBURG CENTRAL WR 011 699 2400 JOHANNESBURG EAST RAND 011 397 6401 PRETORIA 012 362 8819 8893 VEREENIGING 016 422 5667 NELSPRUIT 013 752 8074 5 DURBAN...

Reviews: