4   Installation

Note: Prior to installing your light , HPM recommends that you first observe the overall lighting effectiveness in the dark.  

 

 

 

To connect your garden lights, follow the instructions below:
STEP 1 Place your garden lights in the approximate position you want them to be.
STEP 2 Lay out the cable where you want your lights to be located, remembering to allow sufficient cable to connect to the transformer. Try to avoid laying the 

cable where frequent digging may occur.
STEP 3 - Installation of a 12V Timer (if applicable) 
If a 12 volt timer (HPM Cat No RGL10) is purchased, it must be positioned between 

the transformer and the lights. With the power turned off, connect the wire strands, 

on the end of the timer cable, into the output terminals of the transformer. Secure 

firmly with a screwdriver. 
STEP 4 - Installation of the transformer
Connect the cable to the transformer terminals (or timer, if applicable) by stripping 

back a small amount of insulation from each wire strand (approx. 10mm). Be careful 

not to damage wires. Twist wire strands to prevent loose wire escaping from terminal 

and to help ensure a tight connection. Place stripped ends into screw terminals on 

transformer, or timer, and secure firmly with a screwdriver.
STEP 5 First connect the garden light that will be positioned the furthest away from 

the transformer.
The special connector on each light is designed to make electrical connection by 

piercing the insulation cable as the two halves of the connector are pushed together. (See connection diagrams).

5   Connecting your garden lights

The special jaw lock connectors are designed to make electrical 

connection by piercing the insulation cable as the jaw lock 

connecter is attached. 
STEP 1 Lay the cable flat on one half of the connector as shown.
STEP 2 Lay the other half of the connector on top of the cable, 

upside down, taking care to align the pins into their matching 

holes on the other half. Push together firmly until they lock. 

Check that the two halves are pushed tightly together. (This will 

cause the spikes to deeply pierce into the copper centre of the 

cable and make a solid electrical connection).
STEP 3 Plug the transformer into the powerpoint and check 

whether the furthest positioned garden light operates. (If it doesn’t light up, refer to ‘Troubleshooting’ section). If light does light up, switch off the transformer 

and proceed to connect all the other garden lights using the steps above.
To check each light connection is secure, first turn the transormer on from the powerpoint, then gently wiggle the cable and connector.                                       

(This is perfectly safe - the voltage at this point is very low). If the light flickers, the connection is not firm enough and should be re-connected                              

(repeat ‘Connecting your garden lights’ Steps 1-2).

6   Setup

STEP 1 Switch off the transformer from the powerpoint.
STEP 2 If you wish to cover the cable in the ground, dig a narrow channel, about 100mm deep (just deep enough to hide the cable).
STEP 3 Lay the cable at the bottom of the channel, or fasten the cable to the wall or step using appropriate fixings.
If your cable will be covered in the ground, we recommend, at this point, that you observe the overall lighting effectiveness in the dark before covering the 

channel.

7   Fixing

STEP 1 Choose suitable location for mounting. Mark location for holes using template provided to pitch as shown in 

figure below, drill and fix screws (Use screws and lugs provided)
STEP 2 Ensure the screw head face is proud off the wall face by 5mm. 
STEP 3 Now locate the screw head in the key-holes in the rear of the fixture and press down firmly into place.
If fixture is loose , repeat STEP 2 to adjuct screw height and then follow STEP 3 again.

70

Summary of Contents for HPM RGLLED002

Page 1: ...e fascia assembly STEP 3 Push lamp in firmly into holder STEP 4 Screw bracket bracket back in RGLLED002 3 Cable Layout If your installation includes multiple lights HPM strongly recommends that you limit individual cable lengths to 20 metres or use HPM heavier duty cable otherwise lights may get progressively dimmer towards the end of the cable voltage drop See section for accessories If your inst...

Page 2: ...lf of the connector as shown STEP 2 Lay the other half of the connector on top of the cable upside down taking care to align the pins into their matching holes on the other half Push together firmly until they lock Check that the two halves are pushed tightly together This will cause the spikes to deeply pierce into the copper centre of the cable and make a solid electrical connection STEP 3 Plug ...

Page 3: ...e lights are off 1 The connections at the base of transformer may be loose Tighten firmly 2 There is no power to the powerpoint Consult an electrician 3 You may not have pierced the cable well enough with the metal spikes in the jaw lock connectors Check that the cable insulation has been fully pierced by the spikes Some lights are working one or more are not 1 If one or more of the lights are not...

Page 4: ...ent or a refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired if the goods fail to be of acceptable quality and the failure does not amount to a major failure See the Warranty card enclosed with this product for further details Customer Service For all Customer Service and Technical Support please call ...