Please read carefully

Read through these instructions completely before commencing installation. Retain for futureuse.
1. This product shall be installed in accordance to AS/NZS 3000 WiringRules.
2. Regulations concerning the discharge of air must be fulfilled. Local building codes may require venting to theoutside.
3. This product must be installed at least 2.2m above floorlevel.
4. Do not install within 120cm of a stove or inside a shower recess.
5. Cross Ventilation:

Ventilation products must have an adequate source of external air to ensure ratedperformance.
Steam and air will only be exhausted through the fan if there is sufficient flow of air through the room. Ensure adequate inlets exist through windows,  
vents or under the door. Airflow path from the inlet to the fan should ideally pass over the source of steam or air to be removed from the room.

Restrictions on replacement air entering the room to be ventilated, or pressure-differentials between the room and outside air will significantly reduce  
the exhaust 

fan’s

performance.

6. Compliance with Section 6 Damp Situation of AS/NZS 3000 WiringRules:

No part of the unit may be located directly above any part of the bath or shower recess or enclosure.  
The unit must be installed within zones 2 and 3 only. For further information, refer to AS/NZS 3000.

7. Unit Orientation:

The unit must be installed to ensure the housing outlet and ducting is oriented in parallel to any roofing structures or supports. Refer to image below  
for correct installation orientation. Orientation which forces the unit to be ducted into a 90

°

bend immediately after the fan outlet will cause a significant  

performance reduction.

120

100

80

60

40

20

0

-20

0

50

100

150

200

250

300

B

ack

 P

re

ss

u

re

(P

A

)

Air Flow(m

3

/H)

8. Duct Size and Length:

The unit must be installed with Ø150mm duct using the adaptor supplied to ensure optimum extraction and performance. The maximum recommended  
duct length is 3m. The graph below shows the 

unit’s 

performance with 3m of duct. Longer ducts will reduce the 

unit’s

performance.

9. Duct Routing:

As the back pressure increases the 

unit’s 

performance is reduced. Airflow will be reduced with bends in duct or squashing of duct. Every 90

°

bend/  

elbow results in approx 20% reduction in the 

unit’s

performance.

Please refer to the graph below, an almost linear relationship between back pressure and fan performance proves just how critical correct installation  
of the exhaust fan is in relation toperformance.

EFD01 series

(Ducted- Ø150mm x3m)