Installation

Remove all packaging from the product before commencing installation. Ensure the circuit has been isolated from the 240V mains before  

commencing work.

1. Choose a suitable mounting location. There must be adequate clearances in the wall/ceiling to accommodate the Draft-stopper and/or  

ducting. Refer to section 2 for further information.

2. If ducting through the wall to the outside, refer to instructions in the wall duct kit. Note: the wall kit is available separately, please refer  

to Optional Accessoriessection.

3. The time delay module that is included in EFT150SQSWE is available separately (EF100/150TD), adjustable from 1-to-29 minutes.
4. Make acircular 160mm hole in the wall/ceiling.
5. Remove front cover / fascia by removing fixing screw and cap on the underside of the cover.
6. Remove draft-stopper if not required. Note that the draft-stopper (when fitted) has an effect on the airflow.
7. Make the electrical connections (as per Figures below).

8. Ensure orientation of fan is with arrow pointing up.
9. Fix fan firmly to the wall with the 4 screws provided.
10. Replace front cover/fascia and tighten fixing screw. Replacecap.
11. Switch on and test function. Use a paper tissue held against fan  

inlet to verify suction.

Timer Adjustment

The default setting  

is to 1min(approx).  

Adjust to desired  

time delay.

Active

L

N

Neutral 

T

IM

E

R

MINIMUM

(1 minute)

MAXIMUM

(29 minute)

Fan  

mounting  

orientation

LS 

Switched Active  

from wall switch

N

Neutral

Unswitched Active  

(only used when  
timer module or 
humidity sensor 
module is fitted)

Cableentry 
from rear

Cord entry from  
side for plugand  
lead (knock-out  
provided)

Fixing screw  
position of fascia

Figure 1.

Figure 2. Fan with Timer module and Light fitting

LS

3

N    

2

L   

1

Condition

Timer Module

Humidity sensor

LS is Powered OFF (Initial)

Fan does not run

Fan does not run

LS is Powered ON

Fan runs continuously

Fan runs continuously

LS is Powered OFF 

Fan runs for Preset Time and Switches OFF

Fan runs if relative humidity is above preset 
value and switches OFF when relative humidity 
drops below the preset value plus 2 minutes.

LS is Powered ON and OFF immediately Timer is Reset and fan runs for Preset Time and Switches OFF

LS is Powered OFF (continuously) 

N/A

Fan will run if relative humidity reaches pre-
set value and switches OFF when relative 
humidity drops below the preset value plus 2 
minutes. See optional switch in Fig.3 to disable 
this function.

MINIMUM

60% RH

MAXIMUM

90% RH

Relative Humidity (RH) 
Adjustment

The default factory setting is 

90%. Adjust to desired  RH level

Connection from rear 

bring mains wiring through  

cable entry hole.

Connection from side 

(Fan only) 

use twin flat core  

(H03VV-H2) or circular core (H05VV-F) 2 x 0.75mm

2  

and place under cable clamp provided.

Active

L

N

Neutral 

H

U

M

IDI

T

Y

 S

E

N

S

O

R

Figure 3. Fan with Humidity Sensor module and Light fitting

Optional wall switch

LS

LS

Reviews: