background image

EF100SQWE 

Standard square 
100mm wall fan

Wall Exhaust Fan, 100mm

Cat. EF100SQWE, EF100SQSWE, 

EF100RDWE, EFT100SQSWE

Instruction Manual

1

2

  Product Specifications

  Mounting 

For indoor use only.

*

Measured with 

Φ

100mm ducting. 

Airflow will be reduced with bends in duct, squashing of duct, 

restrictions on replacement air entering the room to be ventilated,  

or pressure-differentials between the room and outside air.

The length of the duct will have an effect on the airflow. When fitted, 

the wall kit (R621/4D) must be at the same height or lower than the 

exhaust fan.

EF100SQSWE, 

*

EFT100SQSWE  

Slimline square 100mm wall 

fan and option with  

*timer intergrated

EF100RDWE 

Round  
100mm wall fan

Model

EF100SQWE

EF100SQSWE

EFT100SQSWE

EF100RDWE

Supply Voltage

230-240VAC 50Hz

Power Rating

14W

Standby Power

0.8W (EFT100SQSWE)

Wall Cut-out Size

Ø110mm

Class of Protection

Class II     

IP Rating

IP44

IP24

IP24

Fascia

Size

158x158mm

158x158mm

Ø190mm

Protrusion 30mm

17mm

17mm

Weight (excl packaging) 500g

450g

450g

Model

EF100SQWE

EF100SQSWE

EFT100SQSWE

EF100RDWE

Exhaust Fan

1 pc

1 pc

1 pc

Draft Stopper

1 pc

1 pc

1 pc

Instruction Manual

1 pc

1 pc

1 pc

Warranty Card

1 pc

1 pc

1 pc

Wall Mount screws & Plugs

1 set

1 set

1 set

Contents

Model

EF100SQWE

EF100SQSWE

EF100RDWE

EFT100SQSWE

Draft Stopper

with

without

with

without

No duct

68

94

81

105

Wall kit R621/4D*  
(350mm of duct)

33

68

48

75

1m of duct*

33

60

46

66

Airflow* (m

2

/hr)

Please read carefully: Read through these instructions completely before commencing installation. Retain for future use. 

This product should be installed by a licensed electrical contractor or similarly qualified person.

These exhaust fans are designed for wall-mounting only.  

They may be vented in to a cavity wall. Alternatively, the fan may be 
ducted through an outside wall (with the addition of ducting and an 
outside grille). Protrusions into wall cavity are as per below figures.

CAUTION:
Regulations concerning the discharge of air must be fulfilled. 

Local building codes may require venting to the outside. Locate in 
accordance with the requirements of the Wiring Rules AS/NZS 3000 
relating to damp situations. 

Note: Steam will only be removed if there is sufficient flow of air 

through the room. Ensure adequate inlet openings in the room are 
provided, for example through windows, vents or under the door. Air-
flow paths from room inlets to fan should ideally pass over surfaces 
where condensation may form.

Draft Stopper

Duct

Ceiling

80mm

120mm

200mm

Wall/Ceiling

Wall/Ceiling

Draft Stopper

Duct

Ceiling

80mm

120mm

200mm

Wall/Ceiling

Wall/Ceiling

Fan only

Fan with  
draft stopper

Wall

Wall

Draft Stopper