INSTRUCTIONS FOR PAC527LFxP4 / 
PAC527LFxP6 Only

Isolated Ground Receptacle

This product incorporates an isolated ground receptacle, 

identified by the orange triangle on its face. This feature may be 

useful to reduce common noise in the connected equipment. Its 
intended use is to reduce electrical noise (electromagnetic 

interference) by purposely insulating the grounding circuit from 

any metallic wiring system. The ground pin of the receptacle is 
connected to the green/yellow wire and is isolated from the 

metal mounting yoke of the receptacle. The accessible metal of 

the product is connected to the green wire. If it is not desired to 
use this feature, connect the green/yellow and green wires 

together. 

References

Application Guide for Isolated Ground Wiring Devices 2007, 
National Electrical Manufacturers Association (NEMA)
IEEE Std 1100

-2005, “IEEE Recommended Practice for 

Powering and Grounding Electronic Equipment” (Emerald 

Book), Section 8.5.3.2.
IEEE Std 142™-2007, “IEEE Recommended Practice for 

Grounding of Industrial and Commercial Power Systems” 

(Green Book), Sections 5.5.1, 5.5.2
NFPA-70, “National Electrical Code”, Article 250.146 

Connecting Receptacle Grounding Terminal to Box.

(D) Isolated Ground Receptacles. Where installed 

for the reduction of electrical noise (electromagnetic 

interference) on the grounding circuit, a receptacle 

in which the grounding terminal is purposefully 

insulated from the receptacle mounting means shall 

be permitted. The receptacle grounding terminal 

shall be connected to an insulated equipment 

grounding conductor run with the circuit conductors. 

This equipment grounding conductor shall be 

permitted to pass through one or more panel boards 

without a connection to the panel board grounding 

terminal bar as permitted in 408.40, Exception, so 

as to terminate within the same building or structure 

directly at an equipment grounding conductor 

terminal of the applicable derived system or service. 

Where installed in accordance with the provisions of 

this section, this equipment grounding conductor 

shall also be permitted to pass through boxes, wire 

ways, or other enclosures without being connected 

to such enclosures.

Informational Note: Use of an isolated equipment 

grounding conductor does not relieve the 

requirement for grounding the raceway system and 

outlet box.

C22.2 No. 1, “Canadian Electrical Code, Part 1”, Rule 10-906 
Bonding conductor connection to circuits and equipment.

(6) A bonding jumper shall be installed to connect 

the bonding conductor to the grounding terminal of 

a receptacle and in such a manner that 

disconnection or removal of the receptacle will not 

interfere with, or interrupt grounding continuity. 

(7) In the case of metallically enclosed systems 

where the grounding path is provided by the metal 

enclosure, a bonding jumper shall be installed to 

bond the grounding terminal of the receptacle to the 

enclosure.

(8) Notwithstanding Sub-rules (6) and (7), the 

bonding jumper, in the case of receptacles having 

grounding terminals isolated from the mounting 

strap required for special equipment, shall be 

permitted to be extended directly back to the 

distribution panel.

WARNING:  

IMPROPER INSTALLATION CAN RESULT IN 

DEATH OR SERIOUS PERSONAL INJURY! This enclosure 

should be installed by qualified personnel.

NOTE:  

The PAC527LFxP4 and PAC527LFxP6 must be 

connected to a 15 Amp branch circuit.

Prepare for Wiring

1.

Remove and save three Phillips head screws holding power 

kit within box. (See Figure 1)

2.

Remove the power kit from the in-wall box. (See Figure 1)

Figure 1  

1

x 3

2

(PAC527LFxP4 
shown as example)

Lower tab  
on power kit

Power kit

4

Fit slots in power kit
lower tab around
two fasteners

Summary of Contents for CHIEF PAC527CVR-KIT

Page 1: ...I N S T A L L A T I O N I N S T R U C T I O N S PAC527L PAC527LF PAC527LFC PAC527LFxP4 PAC527LFxP6 PAC527F KIT PAC527CVR KIT In Wall Box w LeverLock and Accessories PAC527L Series...

Page 2: ...pment Reinforce the structure as required before installing the accessory WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s respo...

Page 3: ...Make sure the outlet is properly grounded See grounding instructions CAUTION This equipment must be installed and assembled by qualified service personnel in accordance with local building and electri...

Page 4: ...ssel Chave de bocas Chiave a punte aperte Steeksleutel Cl fourche By Hand A mano Von Hand Com a m o A mano Met de hand la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschl ssel Chave de ca...

Page 5: ...ate A 4 1 4 x 2 1 2 C 8 06 x 3 8 B 8 06 32 D 4 3 8 Temporary Cover G 1 PAC527F F 1 Template A 4 1 4 x 2 1 2 C 8 06 x 3 8 B 8 06 32 D 4 3 8 Temporary Cover H 1 PAC527FC F 1 Template A 4 1 4 x 2 1 2 C 8...

Page 6: ...7LFxP6 F 1 Template A 4 1 4 x 2 1 2 C 8 06 x 3 8 B 8 06 32 D 4 3 8 Temporary Cover PAC527LFxP6 L 1 Flange F 1 Template M 8 10 24 x 1 4 Temporary Cover PAC527F KIT N 1 Cover PAC527CVR KIT P 2 06 x 1 1...

Page 7: ...are exposed The wall then must be finished around the opening of the box after the box has been installed Locating PAC527L 1 Identify a suitable wall location for the accessory 2 Locate and mark studs...

Page 8: ...n to the panel board grounding terminal bar as permitted in 408 40 Exception so as to terminate within the same building or structure directly at an equipment grounding conductor terminal of the appli...

Page 9: ...hat supplies the outlet Refer to Table 250 122 of the National Electrical Code regarding the appropriate size of the grounding conductor NOTE Pressure terminal or pressure splicing connectors and sold...

Page 10: ...ng a utility knife and remove drywall 5 Check stud depth within the wall If 3 1 2 or greater proceed to PAC527L Box Preparation and Installation If less than 3 1 2 deep proceed to Step 6 6 If present...

Page 11: ...27L into studs through mounting holes in PAC527L Wood studs use 3 16 drill bit Steel studs use 1 4 drill bit 5 Install PAC527L to studs using four 1 4 x 2 1 2 Phillips flat head screws A and four 3 8...

Page 12: ...V to PAC box See Figure 10 Figure 10 4 Slide LeverLock backplanes U into adapter V slots on one side of PAC527L box A See Figure 11 Figure 11 5 Slide LeverLock backplanes into adapter slots on opposi...

Page 13: ...hillips head screws with external teeth M into holes in PAC527L sides See Figure 15 NOTE If the outer edge of the PAC527L needs to be removed use the inner hole for flange attachment See Figure 15 Fig...

Page 14: ...d route through the cover opening s See Figure 18 3 Install cover N and fasten with two 6 x 1 1 4 Phillips self tapping screws P 6 x 1 1 2 button head self tapping screws Q for security two spacers S...

Page 15: ...100 0 6 37 161 9 0 34 8 6 MOUNTING HOLE KNOCKOUT 22 00 558 8 BREAK OFF REGION FOR 2 1 2 WALL INSTALLATION 2 38 60 3 2 38 60 3 2 00 50 8 0 88 22 2 TRADE CONDUIT SIZE 1 2 METRIC CONDUIT SIZE 16mm 1 38...

Page 16: ...SURE 23 26 590 9 15 40 391 1 F F 0 34 8 6 MOUNTING HOLE KNOCKOUT 22 00 558 8 BREAK OFF REGION FOR 2 1 2 WALL INSTALLATION 2 38 60 3 2 38 60 3 2 00 50 8 0 88 22 2 TRADE CONDUIT SIZE 1 2 METRIC CONDUIT...

Page 17: ...0 9 15 40 391 1 F F 0 34 8 6 MOUNTING HOLE KNOCKOUT 1 74 44 1 2 00 50 8 11 00 279 4 0 88 22 2 TRADE CONDUIT SIZE 1 2 METRIC CONDUIT SIZE 16mm 1 38 34 9 TRADE CONDUIT SIZE 1 METRIC CONDUIT SIZE 27mm 1...

Page 18: ...7LFxPx PAC527FxP6 NOTE TWO REMOVABLE PANELS INCLUDED WITH EACH ENCLOSURE SHOWN HERE IN A STACKED CONFIGURATION NOTE TWO REMOVABLE PANELS INCLUDED WITH EACH ENCLOSURE SHOWN HERE IN A STACKED CONFIGURAT...

Page 19: ...NSIONS continued 23 26 590 9 15 40 391 1 13 90 353 0 21 76 552 8 4 75 120 7 0 43 11 0 PAC527F KIT DIMENSIONS INCHES MILLIMETERS 13 38 339 7 13 81 350 8 21 75 552 5 1 50 38 0 5 00 127 0 3 63 92 1 0 69...

Page 20: ...952 225 6000 F 877 894 6918 952 894 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei...

Reviews: