MH202
User guide
9
8
Configuration – Language
The MH202 does not respond to requests via Ethernet (browser,
ping, etc.)
In this page the administrator user can configure the MH202 Web page display language.
The default language is Italian; several other languages are also available.
When the language required is selected and confirmed the Web pages will be displayed in the new
language. If the system is performing other operations a wait message will appear.
Troubleshooting
General checks on switching ON after connection
•
When the SCS BUS is connected, the system LED turns on, and then off again after a few
instants.
It then comes back on again to indicate that the scenario programmer is in operation.
If this does not happen contact the technical after-sales service.
•
Make sure that the SCS system is correctly powered and working.
•
Check that the PC Ethernet cable (used to communicate with the MH202) and the MH202
cable are correctly connected to their RJ45 ports.
•
Check that the PC used to communicate with the MH202 and the MH202 are correctly
configured (in particular, check that the PC network interface is active and that its IP
address and netmask are compatible with those of the device).
•
Also check that the IP addresses set in the PC and the MH202 are not already being used by
other devices in the LAN.