2/2
Cat. Nos: 5 742 02/12/21/30
Arteor
TM
Connected switch without neutral
with dimmer option
Technical data sheet: F02619EN/01
Updated: 03/09/2020
Created: 17/04/2018
6. TECHNICAL CHARACTERISTICS
6.1 Mechanical characteristics
Protection against impacts: IK 04
Protection against solid bodies/liquids: IP 41 assembled product
6.2 Material characteristics
Rocker plate: ABS
Mechanism casing: PC
Halogen-free
UV-resistant
Self-extinguishing:
850°C/30 s for insulating parts holding live parts in place.
650°C/30 s for other insulating components.
6.3 Electrical characteristics
Voltage: 110-230 V~
Power: 300 W
Frequency: 50/60 Hz
Standby consumption: < 0.2 mW
(
*
)
Or 5 lamps max. For comfortable lighting, we recommend using bulbs of the
same type and make.
(
**
)
The ferromagnetic transformers must be charged to more than 60% of their
power. When calculating the permissible power, the ferromagnetic transformer
efficiency must be taken into account. A load must be connected before
programming and using the product.
Zigbee technology 2.4 GHz
to 2.4835 GHz
Power level: < 100 mW
Range: 200 m of unobstructed space
10 m between products indoors
6.4 Climate characteristics
Usage temperature: + 5°C to + 45°C
Storage temperature: 0°C to + 45°C
7. CARE
Clean the surface with a cloth.
Do not use acetone, tar-removing cleaning agents or trichloroethylene.
Resistant to the following products:
Hexane (EN 60669-1), methylated spirit, soapy water, diluted ammonia,
pure bleach diluted to 10%, window-cleaning products, pre-impregnated
wipes.
8. STANDARDS AND APPROVALS
Compliant with installation and manufacturing standards.
See e-catalogue.
The undersigned, LEGRAND, declares that the radio-electric equipment
type (5 742 02/12/21/30) complies with directive 2014/53/EU.
The full text of the EU declaration of conformity is available on the
following website: www.legrandoc.com
R
L
LED
**
240 V~
Max.
300 W
(
*
)
50 W
50 W
300 VA
300 VA
Min.
7 W
5 W
9 W
10 VA
35 VA
100 V~
Max.
150 W
(
*
)
25 W
25 W
150 VA
150 VA
Min.
7 W
5 W
9 W
10 VA
35 VA
Caution: Always test before using special cleaning products.