LEGRAND 488 30 Manual Download Page 1

87045 LIMOGES Cedex

Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88

Technical data sheet: F01131EN/01

Catalogue number(s):  488 30

Updated on: 18/08/2010

Created on: 20/05/2010

1/4

Digital detector - PIR

CONTENTS

1. USE

This device allows a light source to be controlled automatically via a 
controller through the detection of movement in its surveillance zone.
Movement detector with detection angle of: 270° horizontally
Vertical orientation: 90°
Detection type: infra-red (PIR)
Assembly type: wall and ceiling

2. TECHNICAL FEATURES

Voltage: 27 V

=

No load power consumption: 12 mA
Connection between detector and actuator: RJ 45 lead or cable or  
BUS/SCS cable to be fitted with RJ 45 connector 
Surface mounted
Weight: 250 g
Impact resistance: IK04
Penetration by solid and liquid matter: IP55
Usage temperature: -5ºC to +45ºC
Storage temperature: -20ºC to +70ºC

CONTENTS                              Page

1.    Use . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
2. Technical features  . . . . . . . . . . . . . . . .1
3. Overall dimensions. . . . . . . . . . . . . . . .1
4. Connection . . . . . . . . . . . . . . . . . . . . . .2
5. Installation  . . . . . . . . . . . . . . . . . . . . . .2
6. Settings  . . . . . . . . . . . . . . . . . . . . . . . .3
7. Performance. . . . . . . . . . . . . . . . . . . . .4
8. Maintenance. . . . . . . . . . . . . . . . . . . . .4
9. Standards . . . . . . . . . . . . . . . . . . . . . . .4

3. OVERALL DIMENSIONS

82

104

166

PIR Detector 

PIR receiver LED  

(for configuration tool 

or remote control)

PIR transmission LED  

(for configuration tool)

Learn BUTTON

Green detection indicator

Green programming indicator

Summary of Contents for 488 30

Page 1: ...HNICAL FEATURES Voltage 27 V No load power consumption 12 mA Connection between detector and actuator RJ 45 lead or cable or BUS SCS cable to be fitted with RJ 45 connector Surface mounted Weight 250 g Impact resistance IK04 Penetration by solid and liquid matter IP55 Usage temperature 5ºC to 45ºC Storage temperature 20ºC to 70ºC CONTENTS Page 1 Use 1 2 Technical features 1 3 Overall dimensions 1 ...

Page 2: ...18 08 2010 Created on 20 05 2010 2 4 CONTENTS 4 CONNECTION Type of terminals RJ 45 RJ 45 RJ 45 patch and equipment cords RJ 45 BUS SCS connector RJ 45 doubler Option It is possible to manage the detector by infra red remote control 5 INSTALLATION Wall Ceiling 1 4 5 3 3 4 2 1 2 5 6 CLICK CLICK ...

Page 3: ...rt period the LED flashes slowly 2nd press Keep LEARN pressed down for 10 seconds until the LED flashes quickly 6 SETTINGS Parameters Time delay Length of time the load is on after a detection is made Sensitivity Detection range setting Daylight setpoint Value at which the load comes on if light is less than the setting and goes off if it is above this threshold Auto on Auto off mode Comes on auto...

Page 4: ...nvironmental standards EU Directive 2002 96 EC WEEE Waste Electrical and Electronic Equipment EU Directive 2002 95 EC RoHS Restriction of Hazardous Substances Regulations ERP public buildings ERT workplace buildings IGH high rise buildings ATTENTION An initial test is required for the use of other special maintenance products Sensitivity High 75 Sensitivity Very high 100 A B Surface m2 A B Surface...

Reviews: