LEGRAND 488 30 Manual Download Page 4

Catalogue number(s):  488 30

Digital detector - PIR

Technical data sheet: F01131EN/01

Updated on: 18/08/2010

Created on: 20/05/2010

4/4

CONTENTS

8. MAINTENANCE

Keep the lens clean.
Clean the surface with a cloth.
Do not use: acetone, tar-removing cleaning agents or trichloroethylene.
Maintenance with the following products:  - Hexane (En 60669-1), 

- Methylated spirit, 
- Soapy water, 
- Diluted ammonia, 
- Bleach diluted to 10%, 
- Window-cleaning products. 

9. STANDARDS

Directive: CE
Installation standards: NFC 15-100
Product standards: IEC 60669-2-1
Environmental standards: 
-  EU Directive 2002/96/EC: 

WEEE (Waste Electrical and Electronic Equipment)

-  EU Directive 2002/95/EC: 

RoHS (Restriction of Hazardous Substances)

- Regulations:  ERP (public buildings) 

ERT (workplace buildings) 
IGH (high-rise buildings)

ATTENTION:  An initial test is required for the use of other special 

maintenance products.

Sensitivity

High (75%)

Sensitivity

Very high (100%)

A

B

Surface (m

2

)

A

B

Surface (m

2

)

Height (m)

2.5

23

8

197

30

10

263

3

23

8

197

30

10

263

4

23

7

174

30

9

233

5

23

6

158

30

8

210

6

23

5

141

30

7

188

Height

Sensitivity
Low (25%)

Sensitivity

Medium (50%)

A

B

Surface (m

2

)

A

B

Surface (m

2

)

Height (m)

2.5

8

3

66

15

5

131

3

8

3

66

15

5

131

4

8

2

58

15

5

116

5

8

2

53

15

4

105

6

8

2

47

15

4

94

B

A

B

7. PERFORMANCE

Summary of Contents for 488 30

Page 1: ...HNICAL FEATURES Voltage 27 V No load power consumption 12 mA Connection between detector and actuator RJ 45 lead or cable or BUS SCS cable to be fitted with RJ 45 connector Surface mounted Weight 250 g Impact resistance IK04 Penetration by solid and liquid matter IP55 Usage temperature 5ºC to 45ºC Storage temperature 20ºC to 70ºC CONTENTS Page 1 Use 1 2 Technical features 1 3 Overall dimensions 1 ...

Page 2: ...18 08 2010 Created on 20 05 2010 2 4 CONTENTS 4 CONNECTION Type of terminals RJ 45 RJ 45 RJ 45 patch and equipment cords RJ 45 BUS SCS connector RJ 45 doubler Option It is possible to manage the detector by infra red remote control 5 INSTALLATION Wall Ceiling 1 4 5 3 3 4 2 1 2 5 6 CLICK CLICK ...

Page 3: ...rt period the LED flashes slowly 2nd press Keep LEARN pressed down for 10 seconds until the LED flashes quickly 6 SETTINGS Parameters Time delay Length of time the load is on after a detection is made Sensitivity Detection range setting Daylight setpoint Value at which the load comes on if light is less than the setting and goes off if it is above this threshold Auto on Auto off mode Comes on auto...

Page 4: ...nvironmental standards EU Directive 2002 96 EC WEEE Waste Electrical and Electronic Equipment EU Directive 2002 95 EC RoHS Restriction of Hazardous Substances Regulations ERP public buildings ERT workplace buildings IGH high rise buildings ATTENTION An initial test is required for the use of other special maintenance products Sensitivity High 75 Sensitivity Very high 100 A B Surface m2 A B Surface...

Reviews: