background image

2/8

Technical data sheet: F01163EN/01  

Updated: 30/03/2015  

             Created: 07/07/2010

Catalogue number(s): 0 882 30

Configuration tool with screen

3. NAVIGATION

3. NAVIGATION (CONTINUED)

Back to previous page

Takes the current sensor configuration

Sends a configuration to the sensor

Creates a backup file

Provides the website address for the online technical  

documents (www.legrandoc.com)

Deletes a file

Displays a file's parameters

del

Deletes a product from the configuration

learn

Adds a product to the configuration

i

Information

The 4 buttons control the pictogram functions 

displayed above

Sensor parameters

Advanced mode

Files

Sensor PnL

Files

Sensor PnL

Test

Settings

ON 

2-3 s

1
2
3

5

4

6

Sensor parameter

Advanced mode

Files

Sensor PnL

Sensor parameters

1

1

2

3

Time delay

000 H 15 Min 00 Sec

Max. time delay

255 H 59 Min 59 Sec

A

  Daylight setpoint

0500 lux

Max: 1275 lux

C

Sensitivity

Very  high 

< >

US 

High 

< >

HF 

High 

< >

PIR

Very high

High

Medium

Low

B

Detection scheme

E

IR and US < >

Maintain 

 

IR or US  < >

Retrigger 

 

IR   or   US  < >

Initial

IR and US

IR or US

HF only

PIR and HF

PIR or HF

IR only

US only

Mode

D

Walkthrough

Manual  on / Auto  off

Partial  on / Group  off

Auto on/off

Alert

F

ON/OFF

Status change "BEEP" 

on the sensor

Audible

Time delay

Sensitivity

Daylight setpoint

Mode

Detection scheme

Alert

Standby level

Standby time

A

D

E

F

C

B

G
H

 

3.2 Instructions for use

 

3.2.1 Language selection

 

3.1 Pictograms

 

3.2.2 Parameter selection

x 2

Français

English

Italiano

Español

Français

English

Italiano

Español

English

Français

English

Italiano

Español

English

Summary of Contents for 0 882 30

Page 1: ...he product to be measured At a maximum angle of 15 in the axis of the IR transmission and reception LED see figure 4 m 4 m 15 15 Backlit screen automatic switch off Weight 71 g Impact resistance IK04 Operating temperature 5 C to 45 C Storage temperature 20 C to 70 C Recharging Use a mini USB cable not supplied to recharge the configuration tool via a standard USB socket Note Updating software is a...

Page 2: ... 2 3 s 1 2 3 5 4 6 Sensor parameter Advanced mode Files Sensor PnL Sensor parameters 1 1 2 3 Time delay 000 H 15 Min 00 Sec Max time delay 255 H 59 Min 59 Sec A Daylight setpoint 0500 lux Max 1275 lux C Sensitivity Very high US High HF High PIR Very high High Medium Low B Detection scheme E IR and US Maintain IR or US Retrigger IR or US Initial IR and US IR or US HF only PIR and HF PIR or HF IR on...

Page 3: ...oint Value at which the load switches on if the light level is less than the setting and goes off if it is above this setpoint The daylight setpoint can be set up to a maximum of 1275 lux D Mode There are 4 different operating modes Auto on Auto off mode Comes on automatically On detection of a presence if there is insufficient natural light Turns off automatically If no presence is detected and a...

Page 4: ...ode Files Sensor PnL Files 3 Files File name 3 NAVIGATION CONTINUED 3 NAVIGATION CONTINUED The Files menu can be used to display the customised settings saved Up to 26 files can be saved xx H xx MIN xx Sec PIR High US Low Closed loop xxx Lux x Lux Light regulation Mode Detection scheme Detection scheme Detection scheme Alert Time delay Sensitivity Sensitivity Loop type Daylight setpoint Provision ...

Page 5: ...uct documentation is displayed 5 Install the updating file 6 Click on Yes 8 Select the desired language then click OK 7 Click on Yes 9 Click on Next 3 Click on the icon to access software downloading 4 Download the file 3 2 7 Settings 4 1 Installing the software Files Sensor PnL Test Tool config Settings 6 Languages Version Battery A C B Version Firmware X X XX B Languages Français English Italian...

Page 6: ...lete 16 Click on Finish 1 Launch the application shortcut on the Desktop 15 Select Install this driver software anyway 11 Click on Browse to indicate the destination directory 12 Click on Next 13 To create a software icon on your desktop check the corresponding box then click on Next This window summarises the tasks selected earlier 14 Click on Install to confirm these actions or else on Previous ...

Page 7: ...st be switched off Note All technical information is available on Commercial premises office buildings Passage areas and corridors 100 lux Stairs 150 lux Canteens 200 lux First aid room 500 lux Warehouse 100 lux Offices 300 500 lux Conference rooms 500 lux Reception rooms 300 lux Technical drawing 750 lux Manufacturing areas Packaging rooms 300 lux Visual work during manufacturing 1000 lux Assembl...

Page 8: ...lowing products Hexane En 60669 1 Methylated spirit Soapy water Diluted ammonia Bleach diluted to 10 Window cleaning products WARNING Always test before using other special cleaning products Directive CE Product standard EN 60 669 2 1 Environmental standards European Directive 2002 96 EC WEEE Waste Electrical and Electronic Equipment European Directive 2002 95 EC RoHS Restriction of Hazardous Subs...

Reviews: