background image

 DO NOT CHANGE THE POSITION OF THE MICRO SWITCHES (OFF by default)

Pairing with a radio smoke detector alarm
1. Power up the relay board (receiver).

2. Hold down the configuration push button on Relay Cat. No. 0 405 14 for 5 seconds. 3 beeps confirm that the action has 

    been taken into account and the orange LED flashes.  Relay Cat. No. 0 405 14 sends a request to an existing group 

    (smoke detector alarms) 

3. Press the test button on one of the group's smoke detector alarms. 1 long beep confirms completion of the action.

    Relay Cat. No. 0 405 14 is now paired with the smoke detector alarm and automatically switches to installation 

    optimisation mode.

4. Move Relay Cat. No. 0 405 14 towards its planned location and check the quality of reception of the radio signal 

    (see "radio link quality check" table below).  Sequences of 1 to 5 beeps a few seconds apart indicate the quality of the 

    radio link.

5. Mount Relay Cat. No. 0 405 14 at its chosen location.

6. Press the configuration push button on Relay Cat. No. 0 405 14. 4 beeps confirm that it has left installation optimisation 

    mode, and 4 more beeps confirm that it has left configuration mode. The system is now operational. 
- Cancelling the pairing of a smoke detector alarm:

  Press for 10 seconds at stage 2 of the pairing procedure (see above). 4 long beeps confirm it has been cancelled.
- Radio link quality check

  When Relay Cat. No. 0 405 14 is in installation optimisation mode, it sounds 1 to 5 beeps a few seconds apart. Check the 

  quality of the radio link according to the number of beeps sounded by Relay Cat. No. 0 405 14.

1

2

3

4

5

-   -

1 2 3 4

ON

OFF

Testing a single smoke detector alarm:

   This function can be used at any time to check the quality of the radio link between a smoke detector alarm or carbon 

   monoxide detector and Cat. No. 0 405 14.

      - Press the test push button on the smoke detector alarm

      - The test signal is sent to Relay Cat. No. 0 405 14 for 5 minutes.

- Testing all smoke detector alarms: :

  This function can be used to check the quality of the radio link between all detectors paired with Relay Cat. No. 0 405 14.

      - Press (briefly) the push button on Relay Cat. No. 0 405 14

      - The test is activated on all paired smoke detector alarms. An audible signal indicates that transmission is in progress.

  Note: this function is disabled in alarm mode.

- Visual and acoustic identification

Visual signals

Meaning

 Comment

Blue indicator light

   radio activity

-

Red indicator

 light  

steady     

alarm signal received

-

 flashing     test signal received 

 the number of flashes indicates the radio link quality of the last 

 signal received

Acoustic signals

Meaning

Comment

1 to 5-beep sequences / 1 minute  test signal received number of beeps indicates the quality of the last signal received
1 to 5-beep sequences at intervals 

of a few seconds

pairing in progress number of beeps indicates the quality of the signal received

Use

      - To stop the test signal, press the push button on Relay Cat. No. 0 405 14 again.

- Alarm signaling 

   Relay Cat. No. 0 405 14 receive informations coming from paired smoke detector alarm in the same system.

  When an alarm information is sent, the red indicator of the relay Cat. No. 0 405 14 lights fixed.

  Rearming is done automatically around 20 seconds after the alarm origin disappeared.

-

+

+

+   +

Number of beeps

Reception quality

NOT RECOMMENDED

Risk of system failure

Recommended installation

TEST signal

Comment

For 1 minute

Acoustic beeps + flashing red indicator light  The number of beeps and flashes indicate the 

radio link quality of the last signal received. 

Then for 4 minutes

Flashing red indicator light 