background image

32

Customising the light level of keys 1 and 2 x 

From key 1/+

Adjustment of the light level required:

- By a long press on the ON/+ key

- By a long press on the OFF/- key

Saving:

- By pressing simultaneously on keys 1/+ and ON/+

The level of key 1/+ is then recorded

Required

level

Required

level

After switch-

offthe load will 

relight at the 

required level

Required

level

Required

level

After switch-off 

the load will 

relight at the 

required level

From key 2/-

Adjustment of the required light level:

- By a long press on the ON/+ key

- By a long press on the OFF/- key

Saving:

- By pressing simultaneously on keys 2/- and OFF/-

The level of key 2/- is then saved

Action

L

5 s

5 s

Summary of Contents for 0 036 71

Page 1: ...s Conforms to IEC 60669 2 1 0 C to 45 C Do not mix loads oftype and 110 V 500 W 500 W 500 VA 500 VA 230 V 1000 W 1000 W 1000 VA 1000 VA Incandescent lamp Halogen lamp ELV Halogen lamp with ferroma gne...

Page 2: ...ights red ifprotected Ifthe type oflighting load is changed press simultaneously for 10 secs on the ON O buttons on the front The colour of the LED green orange has no bearing on the correct functioni...

Page 3: ...arantees Only use Legrand brand accessories Factory set configuration When first powering up pressing on the ON or OFF keys controls all the remote dimmers cabled into the bus This facility is provide...

Page 4: ...ic transformers must be charged to over 60 of their nominal power Take into account the efficiency ofthe ferromagnetic transformers when calculating the acceptable power example transformer for a 50Wl...

Page 5: ...29 Cabling with single push button Single push button Single pushbutton 100 m max L Short circuit the product...

Page 6: ...30 Local functioning Short press on the ON key Short press on the OFF key Long press on the ON key Long press on the OFF key Action L...

Page 7: ...31 Local functioning continued 66 33 Short press on the 1 key Short press on the 2 key Long press on the 1 key Long press on the 2 key Action L...

Page 8: ...of key 1 is then recorded Required level Required level After switch offthe load will relight at the required level Required level Required level After switch off the load will relight at the require...

Page 9: ...vel memory To activate level memory simultaneous long press on buttons OFF and 1 To deactivate level memory simultaneous long press on buttons ON and 2 After switch off the load will light up again at...

Page 10: ...34 Push button operation Action L L Action Short press Short press Long press Long press...

Page 11: ...35 Short press Long press Short press Push button operation continued Action L L Action L...

Page 12: ...dimmer transmitter Press the LEARN key Press the LEARN key and keep it pressed for 10 seconds The indicator light blinks slowly The indicator light blinks rapidly The indicator light flashes Action Th...

Reviews: