background image

9/11

CONTENTS

Technical data sheet: S000094312EN-1 

Updated: 

Created: 20/09/2017

Cat. No(s): 0 026 54

KNX modular dimmer 2 x 300 W

  9. APPENDIX

Result of the various load tests with Cat. No. 0 026 54

Lamp type

Brand

Photo

Lamp  

reference/Year

Number 

of lamps

Dimmer automatic  

recognition reading

Conformity 

of automatic 

recognition/

Load

Setting(s) to enter for correct 

temperature rise and dimming

Observations and 

comments

BULBS

PHILIPS

Master LEDbulb MV

18W 1521lm

2015

1 to 2

Leading mode
LED with noise reduction (< 40 W)

OK

Check the type of load detected.
Set the minimum light level.

The “Dimmer without 

memory” function is not 

recommended due to the 

lamp technology.
Dimming range can be set 

between 15% and 100%.

3 to 4

Leading mode
LED (< 75 W)

Master LEDbulb MV

17W 1055 lm

2012

1 to 2

Leading mode
LED with noise reduction (< 40 W)

OK

Set the minimum light level  

if necessary.

Dimming range can be set 

between 15% and 100%.

3

Leading mode
LED (< 75 W)

Dimming range can be set 

between 20% and 100%.

Master LEDbulb MV 

13W 1055lm

2015

1 to 3

Leading mode
LED with noise reduction (< 40 W)

OK

Set the minimum light level  

if necessary.

The “Dimmer without 

memory” function is not 

recommended due to the 

lamp technology.
Dimming range can be set 

between 15% and 100%.

4 to 5

Leading mode
LED (< 75 W)

Master LEDbulb MV 

10W 806lm

2015

1 to 4

Leading mode
LED with noise reduction (< 40 W)

OK

Set the minimum light level  

if necessary.

The “Dimmer without 

memory” function is not 

recommended due to the 

lamp technology.
Dimming range can be set 

between 15% and 100%.

5 to 7

Leading mode
LED (< 75 W)

Master LEDluster

4W 250lm

2012

1 to 8

Leading mode
LED with noise reduction (< 40 W)

OK

Check the type of load detected.
Set the minimum light level  

if necessary.

Dimming range can be set 

between 20% and 100%.

Master LEDbulb MV 

DimTone

8W 470lm

2012

1 to 4

Leading mode
LED with noise reduction (< 40 W)

OK

Set the minimum light level  

if necessary.

Dimming range can be set 

between 35% and 100%.

5 to 8

Leading mode
LED (< 75 W)

MASTER Glow 

LEDbulb MV

8W 470lm

2012

1

Leading mode
Compact fluorescent

Not OK

Leading mode + LED with noise 

reduction (< 40 W)
Set the minimum light level  

if necessary.

Dimming range can be set 

between 20% and 100%.

Master LED 

Designer Bulb

7W

2

Leading mode
LED with noise reduction (< 40 W)

OK

Set the minimum light level  

if necessary.

Dimming range can be set 

between 20% and 100%.

TOSHIBA

LDAEU004C2710D

13W 1060 lm

2015

1 to 3

Leading mode
LED with noise reduction (< 40 W)

OK

Set the minimum light level  

if necessary.

Dimming range can be set 

between 10% and 100%.

4 to 5

Leading mode
LED (< 75 W)

LDAEU003C2710D

10.5W 806 lm

2015

1 to 3

Leading mode
LED with noise reduction (< 40 W)

OK

Set the minimum light level  

if necessary.

Dimming range can be set 

between 10% and 100%.

4 to 7

Leading mode
LED (< 75 W)

Summary of Contents for 0 026 54

Page 1: ...he device 3 5 1 1 Description of push buttons 3 5 1 2 Description of LED flashing 3 5 2 Load teach phase 3 5 3 Manual mode 4 5 4 NFC settings 4 5 4 1 Channel configuration 5 5 4 2 Load settings 5 5 4...

Page 2: ...m2 or 2 x 1 5 mm2 BUS consumption 3 mA Table of loads which can be controlled per channel R trailing or leading mode L leading mode Dimmable Dimmable Dimmable LED 12 VAC 240 V Max 300W 200VA or 30 200...

Page 3: ...ntinued 5 1 2 Description of LED flashing Each push button press is associated with a flash and an LED colour The various flashing types and LEDs are detailed in the table below LED Colour Behaviour I...

Page 4: ...1 and 2 can then be switched ON OFF with a short press on the up and down buttons of each channel A long press on these buttons will brighten or dim the light 2 s 2 s 2 s ON OFF 2 s 2 1 To exit manua...

Page 5: ...300 VA max Compact fluorescent 100 W max LED 75 W max LED with noise reduction 40 W max Maximum level 20 to 100 Minimum level 2 to 85 5 4 3 Scene settings This is used to configure the different scene...

Page 6: ...trol unit receives a dimming command OFF time 2 s 1 s 1 H Time taken to go from 100 to 0 when the control unit receives an OFF command Level time 1 s 1 s 1 H Time taken to go from 0 to 100 when the co...

Page 7: ...Automatic by default automatic load recognition Forced if forced mode is chosen it opens the possibility of choosing other options Load commutation Load switching Trailing Edge by default Leading Edge...

Page 8: ...de leading or trailing mode etc 1 Check whether the load is dimmable 2 Check that there is not a mixture of load types The load does not react correctly to the dimming request Inappropriate setting 1...

Page 9: ...EDbulb MV 10W 806lm 2015 1 to 4 Leading mode LED with noise reduction 40 W OK Set the minimum light level if necessary The Dimmer without memory function is not recommended due to the lamp technology...

Page 10: ...5 1 to 8 Leading or trailing mode Transformer LED Not OK 1 to 5 bulbs Leading mode LED with noise reduction 40 W Set the minimum light level if necessary 6 to 8 bulbs Leading mode LED 75 W Set the min...

Page 11: ...and 100 If the transformer makes a buzzing noise switch to trailing mode 1 to 4 max LEGRAND TMDO 50 45 W FERRO Leading mode Transformer OK Set the minimum light level if necessary Dimming range can b...

Reviews: