Step 6. The Gas Supply Line
GAS LINE INSTALLATION
The gas line is brought through the right of the appliance. The gas valve is situated on the right hand
side of the unit and the gas inlet is on the right hand side of the valve. The gas line connection may
be made of rigid pipe, copper pipe (If you are using rigid pipe, ensure that the valve can be removed
for servicing.)
Ensure the appliance shall be installed only by authorised persons and in accordance with the
manufacturer's installation instructions, local gas fitting regulations, municipal building codes,
electrical wiring regulations, AS 5601-2004 - Gas Installations and any other statutory regulations.
When using copper or fl ex connectors use only approved fittings. Always provide a union so that
gas lines can be easily disconnected for servicing. Flare nuts for copper lines are usually considered
to meet this requirement.
Important: Always check for gas leaks with a soap and water solution or gas leak detector.
Do not use open flame for leak testing.