![Legato SMS Basic User Manual Download Page 28](http://html.mh-extra.com/html/legato/sms-basic/sms-basic_user-manual_1868833028.webp)
GSM SMS Alarm Messenger
SMSPro (Version 7)
28
11.16)
Input Voltage Alert Level Setup
Command: PWD:
XXXX
,POWVL:
mmmm
%
XXXX Password
Mmmm
when power input is lower than this value, alarm is triggered
Example:
PWD:1234,POWVL:8.25%
Password:
1234
When the battery voltage is lower than 8.25VDC, alarm is triggered.
The reactive will be setup by the command above.
11.17)
Arm/Disarm Setup
Command: PWD:
XXXX
,ARM%
XXXX Password
Example:
PWD:1234,ARM%
Password: 1234
Unit is armed, and in alert status
Command: PWD:
XXXX
,DISARM%
XXXX Password
Example:
PWD:1234,DISARM%
Password: 1234
Unit is disarmed, and no alarm is reported
11.18)
System Parameters RESET
PWD:XXXX,PARAMETER
&
%
This is to reset the parameters and password into default setting.
[SMS Message received]
Parameter initialize success!
11.19)
System Version Check
PWD:XXXX,CHECKVR%
[SMS Message received]
SD41 V7.1_3_B 2010/01/28