LEGACY SPA - DIAGNOSTIC MESSAGES 

Enterprise SE & Inspire SE

3

aCtIOn rEQuIrED
The control panel will be disabled until 
power returns. Spa settings will be  
preserved until next power up. 

After the pump has been running  
for 2 minutes, the temperature will  
be displayed.

DO NOT ENTER THE WATER. Remove the 
spa cover and allow water to cool. Once 
the heater has cooled, reset by pushing 
any button. If spa does not reset, shut 
off the power to the spa and call your 
dealer or service organization.

DO NOT ENTER THE WATER. Remove the 
spa cover and allow water to cool. At 
107°F/42°C, the spa should automatically 
reset. If spa does not reset, shut off the 
power to the spa and call your dealer  
or service organization.

No action required. The pump(s) will  
automatically activate regardless of  
spa status.

If the problem persists, contact your 
dealer or service organization. (May 
appear temporarily in an overheat  
situation and disappear when the  
heater cools.)

If the problem persists, contact your 
dealer or service organization. (May 
appear temporarily in an overheat  
situation and disappear when the  
heater cools.)

MEanInG
No message on display. 
Power has been cut off 
to the spa.

Temperature 
unknown. 

“Overheat” - The spa  
has shut down. One 
of the sensors has 
detected 118°F/48°C at 
the heater. 

“Overheat” - The spa 
has shut down. One of 
the sensors has detected 
that the spa water is 
110°F/43°C. 

“Ice” - Potential freeze 
condition detected. 

Spa is shut down. The 
sensor that is plugged 
into the Sensor “A” 
jack is not working. 

Spa is shut down. The 
sensor that is plugged 
into the Sensor “B” 
jack is not working. 

MESSaGE

LEGACY SPA - DIAGNOSTIC MESSAGES 

Enterprise SE & Inspire SE

4

aCtIOn rEQuIrED
If the problem persists, contact your 
dealer or service organization. 
 
 
 
 

Check water level in spa. Refill if  
necessary. If the water level is okay, 
make sure the pumps have been primed. 
If problem persists, contact your dealer 
or service organization. 

Follow action required for “

”  

message. Heating capability of the spa 
will not reset automatically; you may 
press any button to reset. 
 
 
 

Check water level in spa. Refill if  
necessary. If water level is okay, make 
sure the pump(s) have been primed. 
Press any button to reset, or this message 
will automatically reset within 15 minutes. 
If problem persists, contact your dealer 
or service organization.

Follow action required for “

”  

message. Spa will not automatically 
reset. Press any button to reset.

MEanInG
Sensors are out of  
balance. If alternating 
with spa temperature, 
it may just be a  
temporary condition.  
If flashing by itself,  
spa is shut down.

A significant difference 
between tempera-
ture sensors has been 
detected. This could 
indicate a flow  
problem.

Persistent low flow 
problems. (Displays on 
the fifth occurrence of 

” message within 

24 hours.) Heater is 
shut down, but other 
spa functions continue 
to run normally.

Possible inadequate 
water, poor flow, or air 
bubbles in detected in 
the heater. Spa is shut 
down for 15 minutes. 
 

Inadequate water 
detected in heater. 
(Displays on third 
occurrence of “

” 

message.) Spa is  
shut down.

MESSaGE

Warning! Shock Hazard! no user Serviceable parts. Do not attempt service of this 
control system. Contact your dealer or service organization for assistance. Follow all 
owner’s manual power connection instructions. Installation must be performed by  
a licensed electrician and all grounding connections must be properly installed.