Lefroy Brooks R1-4033 Installation, Operating,  & Maintenance Instructions Download Page 9

9

Guarantee

Guarantee of Quality

This product is guaranteed against faulty materials and workmanship for 12 months from date 
of purchase. For the guarantee to be valid, the unit must be installed by a competent person, in 
accordance with the instruction booklet.

Any part found to be defective during the guarantee period, will (at our option) be repaired or 
replaced, free of charge, provided the unit has been installed, and properly used in
accordance with the instruction booklet.

Our products correspond to the valid technical and water supply standards as well as the relevant 
approvals requirements. We guarantee them to be free of design and production faults at the time 
of delivery and that with correct use and care in accordance with our printed instructions they will 
function reliabl

y.

Guarantee period

s

The guarantee is valid in private homes for 5 years from the purchase date. Proof of purchase 

   has to be provided when making a guarantee claim.

s

 By use in commercial or institutional applications the guarantee is valid for 1 year after first use. 

 

To make a guarantee claim, proof of purchase or, the beginning of use is required. 

Not Covered by this Guarantee

Damage or defects arising from incorrect installation, improper use or lack of maintenance.
Installed product damaged in transit Consequential loss, damage or product removal and installation 
costs.

Lefroy Brooks is not responsible for any on site labour charges.

Summary of Contents for R1-4033

Page 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS R1 4033 DECK FLOW CONTROL ROUGHS 1 PAIR TO SUIT K1 1026 M1 1026 X1 1026 CW 1026 CB 1026...

Page 2: ...2 Contents Dimensions 3 Installation Procedure 4 Parts List 6 Fault Finder 7 Safety Tips Care and Maintenance 8 Guarantee 9...

Page 3: ...4 223mm 8 12 203 2mm 304 8mm 1 2 5 3 8 12mm 136mm 1 2 14NPSM 2B 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to change without no...

Page 4: ...t plumbing products be installed by a licensed professional Shut off main water supply before installation 1 Remove the protective bubble bag cap and top mounting nut from body assembly 2 Install the...

Page 5: ...ies relying on speci c gauge A B D supplied as the gure indicated to make sure they can t with the trim in various ranges After that tighten xing nuts from below by wrench Gauge A 027105 for M1 1025 M...

Page 6: ...22 5 Nut 054026 6 Body 061113H 50 7 Body 061113C 50 8 Cartridge 507724 50 9 Rubber protective cap 038103 10 Gauge A for Fleetwood M2 series 027105 11 Gauge B for Kafka K1 XO X1 series 027104 12 Gauge...

Page 7: ...7 Fault Finder Fault Cause Recti cation Leaks around handle Cartridge has come loose or damaged Tighten reinstall the cartridge or replacement the cartridge if it is damaged...

Page 8: ...ater pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom faucet is...

Page 9: ...hem to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably Guarantee period s The...

Page 10: ...s are protected by law and the use or reproduction outside the terms of an agreement is prohibited The right to modify designs and dimensions is reserved Christo Lefroy Brooks is a member of ACID Anti...