Page 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS R1 4027 CROSS HANDLE WALL MOUNTED 3 HOLE BASIN MIXER ROUGH TO SUIT M1 1110...

Page 2: ...2 Contents Dimensions 3 Instalation Procedure 4 Parts List 6 Fault Finder 7 Safety Tips Care and Maintenance 8 Guarantee 9...

Page 3: ...9mm 140mm 202mm 101mm 15mm 92mm 172mm 115mm 131mm 52 44mm 87 5mm Protective Cap Protective Cap Protective Cap 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design a...

Page 4: ...ation Procedure Lefroy Brooks always recommends that plumbing products be installed by a licensed professional Shut off main water supply before installation 1 Before installation make sure that the 2...

Page 5: ...tallation Procedure Lefroy Brooks always recommends that plumbing products be installed by a licensed professional Shut off main water supply before installation 3 Connect the inlets with water supply...

Page 6: ...aptor 077126W O ring 072042N Protective cap 045225 1 2 3 4 5 6 Protective cap 038007 Adaptor 067733 Retainer nut 016231 Cartridge assembly 507909N Teflon tape 203000 Screw 008013 7 8 9 10 11 12 13 2 1...

Page 7: ...e Rectification Drips from spout Gasket is misfitted or damaged Check for gasket placement Leaks around handle Cartridge has come loose or damaged Tighten reinstall the cartridge or replacement the ca...

Page 8: ...in water pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom fauce...

Page 9: ...them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably Guarantee period The...