background image

9

Guarantee

Guarantee of Quality

This product is guaranteed against faulty materials and workmanship for 12 months from date 
of purchase. For the guarantee to be valid, the unit must be installed by a competent person, in 
accordance with the instruction booklet.

Any part found to be defective during the guarantee period, will (at our option) be repaired or 
replaced, free of charge, provided the unit has been installed, and properly used in
accordance with the instruction booklet.

Our products correspond to the valid technical and water supply standards as well as the relevant 
approvals requirements. We guarantee them to be free of design and production faults at the time 
of delivery and that with correct use and care in accordance with our printed instructions they will 
function reliabl

y.

Guarantee period

s

The guarantee is valid in private homes for 5 years from the purchase date. Proof of purchase 

   has to be provided when making a guarantee claim.

s

 By use in commercial or institutional applications the guarantee is valid for 1 year after first use. 

 

To make a guarantee claim, proof of purchase or, the beginning of use is required. 

Not Covered by this Guarantee

Damage or defects arising from incorrect installation, improper use or lack of maintenance.
Installed product damaged in transit Consequential loss, damage or product removal and installation 
costs.

Lefroy Brooks is not responsible for any on site labour charges.

Summary of Contents for R1-4007

Page 1: ...LLATION OPERATING MAINTENANCE INSTRUCTIONS R1 4007 LEVER 5 HOLE BATH SET WITH PULL OUT HAND SHOWER DECK DIVERTER ROUGH TO SUIT K1 2201 X1 1056 M1 2201 M1 2202 M1 2205 M1 2206 M1 2208 M1 2209 M2 2201 M2 2202 ...

Page 2: ...2 Contents Dimensions 3 InstalLation Procedure 4 Parts List 6 Fault Finder 7 Safety Tips Care and Maintenance 8 Guarantee 9 ...

Page 3: ...4NPSM 2A 1 1 4 UNEF 2A 3 4 14NPSM 2A 7 15 16 202mm 1 2 14NPSM 2A 3 4 14NPSM 2A 2 1 2NPSM 2A 1 2 NPT 2B M5X1 6g 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to change without notice as part of the company s product development process ...

Page 4: ...embly and shower hose top 2 Install the body through mounting hole from below and attach top mounting nut from top 3 Adjust position of the bodies relying on specific gauge A B C supplied as the figure indicated to make sure they can fit with the trim in various ranges After that tighten fixing nuts from below by wrench Gauge A 027105 for M2 2200 M2 2201 M2 2202 Gauge B 027104 for K1 2200 K1 2201 X1 1...

Page 5: ...to two outlets on the diverter shank 5 Replace the protective bubble bag body and spout protective caps plugs and shower hose top to prevent dirt ingress or water leakage during construction 6 Connect inlet and outlet with flexible hoses Warning When installing flexible hose please notice 1 There should be no torsion or deformation 2 Do not fold into a V or L shape 3 Do not use if there is any crack...

Page 6: ...N 17 Adaptor 039008 18 Flexible hose 105137 19 Cartridge C 507724 50 20 Shank 061113C 50 21 Plug 028599 22 Ring 200197 23 Shank 014638 24 Ring 200198 25 Clip 012294 26 Shower hose 105786 27 O ring 048099R 28 Shell 033095 29 Shank 014546 30 O ring 072007N 31 Diverter valve 208141 32 O ring 063026N 33 Spring 005000 34 Washer 060067 35 Plug 101000 36 O ring 004535N 37 Shell 033764 38 O ring 004074N 3...

Page 7: ...7 Fault Finder Fault Cause Rectification Leaks around handle Cartridge has come loose or damaged Tighten reinstall the cartridge or replacement the cartridge if it is damaged ...

Page 8: ... water pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom faucet is designed for years of trouble free performance Keep it looking new by cleaning it periodically with a soft cloth Avoid abrasive cleaners wire wool and harsh chemicals as these will dull the finish an...

Page 9: ...them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably Guarantee period s The guarantee is valid in private homes for 5 years from the purchase date Proof of purchase has to be provided when making a guarantee claim s By use in commercial or institutional applications the gua...

Page 10: ...ts are protected by law and the use or reproduction outside the terms of an agreement is prohibited The right to modify designs and dimensions is reserved Christo Lefroy Brooks is a member of ACID Anti Copying in Design LEFROY BROOKS INC 1828 TROUTMAN STREET RIDGEWOOD NY 11385 TELEPHONE 718 302 5292 FAX 718 302 4177 COPYRIGHT LBIP LTD 2014 718 302 5292 www lefroybrooks com ...