Safety Tips

If you are soldering during faucet installation,remove cartridges, seats, gaskets and washers prior to 
applying flame, otherwise you will void the warranty.

Cover drain openings to avoid losing small parts.

When cutting or soldering pipe, use safety glasses to protect your eyes.

Important Points

Prior to beginning installation. turn off the cold and hot water lines and open the old faucet to release
built-up pressure.

Overtightening nuts may cause damage.

Wrap all threaded connections with pipe tape available at your local plumbing supply store.
Always wrap in a clockwise direction. The fittings should be installed by a state-licenced plumber.

Please note:
When there is a difference in water pressure between hot and cold supplies to the mixing valve, the 
pressures should be equalized by a plumber in accordance with best practice and legislation.

Maintenance

Your new bathroom faucet is designed for years of trouble-free performance. Keep it looking new by 
cleaning it periodically with a soft cloth. Avoid abrasive cleaners, wire wool and harsh chemicals as 
these will dull the finish and void your warranty.

Routine Maintenance

The frequency and extent of attention required will vary according to prevailing site and operational 
conditions, however a 12 monthly maintenance schedule is recommended.

If the product has operated satisfactorily for some time, but performance has been degraded, please 
check the Fault Finder section to identify the problem.

Maintenance Check List

  •  Worn or damaged seals and washers
  •  Damaged seal faces
 • 

Thread 

wear

 • 

Incorrect 

adjustment

 • 

Component 

failure

  •  Debris or limescale build-up

Summary of Contents for M2-1111

Page 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS M2 1111 LEVER WALL MOUNTED 3 HOLE BASIN MIXER TRIM TO SUIT R1 4016 ROUGH...

Page 2: ...2 RQWHQWV Dimensions 3 InstalLation Procedure 4 Parts List 6 Fault Finder 7 Safety Tips Care and Maintenance 8 Guarantee 9...

Page 3: ...4 83 2mm 2 3 8 60mm 1 15 16 50mm 8 203 3mm 100 10 2 50 7mm 3 4 19mm 3 LPHQVLRQV in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to change withou...

Page 4: ...a licensed professional Shut off main water supply before installation 1 Once the front wall is nished remove the protective caps for installing the trim 2 Disassemble central canopy and spout by loos...

Page 5: ...ecommends that plumbing products be installed by a licensed professional Shut off main water supply before installation Steps 4 5 4 Install the handle by xing screw through the stem extension 5 After...

Page 6: ...0N 9 Screw 008488 10 Stem extension 110473 11 Aerator housing 305856 54 12 Aerator insert 553661N 13 Oil seal 010519N 14 Spout 139325W 15 Screw 008198 16 O ring 063066N 17 Canopy 000115 18 Nut 009620...

Page 7: ...cation Drips from spout Gasket is mis tted or damaged Check for gasket placement Aerator leaks or has an inconsistent water ow pattern Aerator is dirty or mis tted Unscrew the aerator to check rubber...

Page 8: ...n water pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom faucet...

Page 9: ...them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably Guarantee period The...