Guarantee

Guarantee of Quality

This product is guaranteed against faulty materials and workmanship for 12 months from date 
of purchase. For the guarantee to be valid, the unit must be installed by a competent person, in 
accordance with the instruction booklet.

Any part found to be defective during the guarantee period, will (at our option) be repaired or 
replaced, free of charge, provided the unit has been installed, and properly used in
accordance with the instruction booklet.

Our products correspond to the valid technical and water supply standards as well as the relevant 
approvals requirements. We guarantee them to be free of design and production faults at the time 
of delivery and that with correct use and care in accordance with our printed instructions they will 
function reliabl

y.

Guarantee period

s

The guarantee is valid in private homes for 5 years from the purchase date. Proof of purchase 

   has to be provided when making a guarantee claim.

s

 By use in commercial or institutional applications the guarantee is valid for 1 year after first use. 

 

To make a guarantee claim, proof of purchase or, the beginning of use is required. 

Not Covered by this Guarantee

Damage or defects arising from incorrect installation, improper use or lack of maintenance.
Installed product damaged in transit Consequential loss, damage or product removal and installation 
costs.

Lefroy Brooks is not responsible for any on site labour charges.

Summary of Contents for M1-4716

Page 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS M1 4716 ML 1517 LEVER KITCHEN BRIDGE MIXER...

Page 2: ...2 Contents Dimensions 3 InstalLation Procedure 4 Parts List 7 Fault Finder 8 Safety Tips Care and Maintenance 9 Guarantee 10...

Page 3: ...A 3 4 19mm 6 3 16 157mm 1 25mm 3 4 19mm 10 254mm 13 9 16 345mm R4 5 8 R117 5m m 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to c...

Page 4: ...ff main water supply before installation 1 Take out product from the box Turn the spout to the right front position as the gure shows Tighten the xing set screw to secure the spout in position 2 Insta...

Page 5: ...by a licensed professional Shut off main water supply before installation 3 Attach escutcheons to the legs then install the legs to the deck 4 After placing the legs in the right position x the legs w...

Page 6: ...be installed by a licensed professional Shut off main water supply before installation 5 After installing faucet remove aerator and open the hot and cold supplies Check for leaks Turn on faucet handle...

Page 7: ...7 Stem extension 110461 8 Cartridge C 507176W 9 Body 002678W 10 Screw 008264 11 Clip 012112N 12 O ring 004005N 13 Clip 012060 14 Adaptor 018227 15 O ring 063066N 16 Spout assembly 139889W 17 Oil seal...

Page 8: ...sket placement Leaks around handle Cartridge has come loose or damaged Tighten reinstall the cartridge or replacement the cartridge if it is damaged Aerator leaks or has an inconsistent water ow patte...

Page 9: ...ater pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom faucet is...

Page 10: ...them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably Guarantee period s Th...

Page 11: ...s are protected by law and the use or reproduction outside the terms of an agreement is prohibited The right to modify designs and dimensions is reserved Christo Lefroy Brooks is a member of ACID Anti...