wall surface
80mm~105mm
Hot supply
Outlet
Cold supply
136mm~140mm
100mm~110mm
1
2
3
4
4
Steps 1-4
Installation Procedure
Lefroy Brooks always recommends that plumbing products be installed by a licensed professional.
Shut off main water supply before installation.
1
Position valve into the wall as the figure instructed.
2
Connect Water Supply Piping.
3
Cut a hole on the wall surface for fitting the trim kit. The hole dimension is as shown in figure 3.
4
Throw away the protective caps only when the building construction is completed and you are
ready to fit the trim kit. Take out the stopper.