Lefroy Brooks M1-4302 Installation, Operating,  & Maintenance Instructions Download Page 4

3

1

2

78mm~103mm

Water outlet

Water outlet

Hot water 

supply pipe

Cold water 

supply pipe

     Stopper A 
(marked #049000)

     Stopper B 
(marked #049001)

Washer C

4

Dimple on valve stem

Notch

     Stopper A 
(marked #049000)

6

5

REMOVE CAP ONLY, KEEP THE REST OF 

THE MUD GUARD AS IT IS NEEDED TO 

HOLD THE TRIM FIXING SCREWS.

4

Steps 1-6

Installation Procedure

Lefroy Brooks always recommends that plumbing products be installed by a licensed professional. 
Shut off main water supply before installation.

1

 

While placing the valve into wall, make sure that the distance between the wall surface and the    

 

back of the valve is between 78~103mm as the figure indicates.

2

 

Connect the valve with water pipes.

3

 

Throw away the protective cap only when the building construction is completed and you are  

 

 

ready to fit the trim kit in. 

 

REMOVE CAP ONLY, KEEP THE REST OF THE MUD GUARD AS IT IS NEEDED TO HOLD THE TRIM    

 

FIXING SCREWS.

4

 

Temperature Limiting Device: Remove washer C, then take off stopper A & B.

5

 

Turn the valve stem so that the round dimple on the stem is at the top side.

6

 

Install stopper A onto valve stem. Notch on stopper A should point upward.

Summary of Contents for M1-4302

Page 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS M1 4302 CROSS HANDLE PRESSURE BALANCE WITH LEVER 2 WAY DIVERTER TRIM ONLY TO SUIT M1 4101 ROUGH...

Page 2: ...2 Contents Dimensions 3 Instalation Procedure 4 Cartridge Removal Troubleshooting 6 Temperature Limiting Device 8 Parts List 9 Fault Finder 10 Safety Tips Care and Maintenance 11 Guarantee 12...

Page 3: ...1 1 4 31 7mm 3 76mm 1 2 12mm 1 7 16 36mm 1 9 16 3 1 8 40mm 80mm 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to change without no...

Page 4: ...fore installation 1 While placing the valve into wall make sure that the distance between the wall surface and the back of the valve is between 78 103mm as the figure indicates 2 Connect the valve wit...

Page 5: ...ion range Stopper B marked 049001 10 5 Installation Procedure Steps 7 10 Lefroy Brooks always recommends that plumbing products be installed by a licensed professional Shut off main water supply befor...

Page 6: ...13 Lefroy Brooks always recommends that plumbing products be installed by a licensed professional Shut off main water supply before installation 11 Install the stem extension and canopies 12 Fix the...

Page 7: ...388 8 Screw 008186 9 Front plate 006584 50 10 Oil seal 010940 11 Spacer 013816 12 Screw 008115 13 Stem extension 110389 14 Canopy 018961 15 Set screw 065086 16 Canopy 018959 50 17 Adjusting ring 10429...

Page 8: ...lt Finder Fault Cause Rectification Wobbling of handle The fixing screw comes loose Check for fixing screw and re tighten it properly Wobbling of canopy The canopy comes loose Check and tighten the ca...

Page 9: ...in water pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom fauce...

Page 10: ...them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably Guarantee period The...

Page 11: ...s are protected by law and the use or reproduction outside the terms of an agreement is prohibited The right to modify designs and dimensions is reserved Christo Lefroy Brooks is a member of ACID Anti...