3

1

2

     Stopper A 
(marked #049000)

     Stopper B 
(marked #049001)

Washer C

4

Dimple on valve stem

Notch

     Stopper A 
(marked #049000)

6

5

REMOVE CAP ONLY, KEEP THE REST OF 

THE MUD GUARD AS IT IS NEEDED TO 

HOLD THE TRIM FIXING SCREWS.

Water outlet

Water outlet

Hot water 

supply pipe

Cold water 

supply pipe

84mm~109mm

4

Steps 1-6

Installation Procedure

Lefroy Brooks always recommends that plumbing products be installed by a licensed professional. 
Shut off main water supply before installation.

1

 

While placing the valve into the wall, make sure that the distance between the wall surface and    

 

the back of the valve is between 84~109mm as the figure indicates.

2

 

Connect the valve with water pipes.

3

 

Throw away the protective cap only when the building construction is completed and you are  

 

 

ready to fit the trim kit in. 

 

REMOVE CAP ONLY, KEEP THE REST OF THE MUD GUARD AS IT IS NEEDED TO HOLD THE TRIM    

 

FIXING SCREWS.

4

 

Temperature Limiting Device: Remove washer C, then take off stopper A & B.

5

 

Turn the valve stem so that the round dimple on the stem is at the top side.

6

 

Install stopper A onto valve stem. Notch on stopper A should point upward.

Summary of Contents for M1-4101

Page 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS M1 4101 TWO HANDLE PRESSURE BALANCE ROUGH WITH 2 WAY DIVERTER TO SUIT M1 4302 M1 4303...

Page 2: ...2 Contents Dimensions 3 Instalation Procedure 4 Cartridge Removal Troubleshooting 6 Parts List 7 Fault Finder 8 Safety Tips Care and Maintenance 9 Guarantee 10...

Page 3: ...6 78mm 6 5 16 160mm 6 1 4 158mm 2 3 4 70mm 5 3 8 137mm 3 1 16 4 1 16 78 103mm 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to cha...

Page 4: ...re installation 1 While placing the valve into the wall make sure that the distance between the wall surface and the back of the valve is between 84 109mm as the figure indicates 2 Connect the valve w...

Page 5: ...with 60 operation range Stopper B marked 049001 5 Installation Procedure Steps 7 9 Lefroy Brooks always recommends that plumbing products be installed by a licensed professional Shut off main water s...

Page 6: ...le rubber gasket is not left behind inside the cylindrical recess of the rough 2 Turn slot of plastic cover C 90 degree anti clockwise and remove 3 Take out the balance sub assembly and clean the pres...

Page 7: ...Spring 005006 7 Protective rubber cap 038008 8 Adjusting ring 104291 9 Diverter cartridge 507775N 10 Set screw 075039 11 Body 076697 12 O ring 048017 13 Adaptor 057838 14 Body assembly 061847 15 O ri...

Page 8: ...old is too low Inspect check valves to ensure they are fully open flush the system Remove and clean showerheads May need to replace if clogged Check for water pressure and adjust to proper pressure le...

Page 9: ...in water pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom fauce...