background image

7

Safety Tips, Care and Maintenance

Safety Tips

If you are soldering during faucet installation,remove cartridges, seats, gaskets and washers prior to 
applying flame, otherwise you will void the warranty.

Cover drain openings to avoid losing small parts.

When cutting or soldering pipe, use safety glasses to protect your eyes.

Important Points

Prior to beginning installation. turn off the cold and hot water lines and open the old faucet to release
built-up pressure.

Overtightening nuts may cause damage.

Wrap all threaded connections with pipe tape available at your local plumbing supply store.
Always wrap in a clockwise direction. The fittings should be installed by a state-licenced plumber.

Please note:
When there is a difference in water pressure between hot and cold supplies to the mixing valve, the 
pressures should be equalized by a plumber in accordance with best practice and legislation.

Maintenance

Your new bathroom faucet is designed for years of trouble-free performance. Keep it looking new by 
cleaning it periodically with a soft cloth. Avoid abrasive cleaners, wire wool and harsh chemicals as 
these will dull the finish and void your warranty.

Routine Maintenance

The frequency and extent of attention required will vary according to prevailing site and operational 
conditions, however a 12 monthly maintenance schedule is recommended.

If the product has operated satisfactorily for some time, but performance has been degraded, please 
check the Fault Finder section to identify the problem.

Maintenance Check List

  •  Worn or damaged seals and washers
  •  Damaged seal faces
  •  Thread wear
  •  Incorrect adjustment
  •  Component failure
  •  Debris or limescale build-up

Summary of Contents for M1-1011

Page 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS M1 1011 LEVER TWO WAY WALL DIVERTER TRIM ONLY TO SUIT R1 4000 ROUGH...

Page 2: ...2 Contents Dimensions 3 Instalation Procedure 4 Parts List 7 Fault Finder 6 Safety Tips Care and Maintenance 7 Guarantee 8...

Page 3: ...5 8 117 5mm 1 7 8 47mm 1 4 7mm 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to change without notice as part of the company s pr...

Page 4: ...products be installed by a licensed professional Shut off main water supply before installation 1 Throw away the protective cap only when the building construction is completed and you are ready to f...

Page 5: ...4 3 7 8 9 1 6 5 Escutcheon 071279 54 O ring 004044 Adaptor 057507 Adaptor 067773 Clip 012242 1 2 3 4 5 Canopy 018014 Handle 029686 Set screw 292598 Allen key 031000 6 7 8 9 5 Parts List Exploded view...

Page 6: ...lt Finder Fault Cause Rectification Wobbling of handle The fixing screw comes loose Check for fixing screw and re tighten it properly Wobbling of canopy The canopy comes loose Check and tighten the ca...

Page 7: ...in water pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom fauce...

Page 8: ...them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably Guarantee period The...

Page 9: ...s are protected by law and the use or reproduction outside the terms of an agreement is prohibited The right to modify designs and dimensions is reserved Christo Lefroy Brooks is a member of ACID Anti...

Reviews: