T
H
E R
M O S T
A
I
C
L
E
F R
O Y B R O
O
K
S
M
D E
I N E N G
L A
N
D
MADE IN
LE
FR
Y
BRO
OKS L
IM
IT
ED
E N
G L A N D
50mm
105mm
33mm
107mm
Ø90mm
15mm Copper
153mm (Connaught – CT)
148mm (Mackintosh – MK)
COLD
HOT
200mm
G¾
2
DIMENSIONS
Not to scale
Shown with CT8700
Page 1: ...CT 8700 MK 8700 EXPOSED THERMOSTATIC SHOWER VALVE WITH CERAMIC LEVER INSTALLATION GUIDE...
Page 2: ...O K S M A D E I N E N G L A N D H O T C O L D MADE IN L E F R O Y BROOKS L I M I T E D E N G L A N D 50mm 105mm 33mm 107mm 90mm 15mm Copper 153mm Connaught CT 148mm Mackintosh MK COLD HOT 200mm G 2 D...
Page 3: ...1085mm maximum CT MK 8702 CT MK 8720 CT MK 8703 CT MK 8705 All dimensions are taken from centres HOT COLD HOT COLD 200mm 200mm Note On 8720 the hot is on the right and cold on the left HOT COLD HOT C...
Page 4: ...ermostatic cartridge cover PTS025 MK Handwheel PTS020 Lock washer PTS022 Temperature stop LB2750 Thermostatic cartridge PTS021 Lock nut PTS007 Screw PTS004 White lever UPPER ceramic only PTE016 Black...
Page 5: ...ICAL FLOW RATES Note Balanced pressures shown are applied directly to the hot and cold inlets flow rates indicated are free flowing and may vary subject to restrictions created by installation pipewor...
Page 6: ...tridge replacing the non return valve sections Time between servicing can vary as it is subject to usage and water quality Servicing kits are available reference code PTE021 or refer to exploded view...
Page 7: ...he external joints For this reason we recommend that all connections to and from the valve are pressure tested Access It is important to leave suitable clearance and access to the valve and connection...
Page 8: ...the cartridge spline whilst measuring the temperature of the water Ideally the temperature measurement should be taken using a digital thermometer Duty of care Legislation dictates recommendations an...
Page 9: ...rtridge spline with the safe temperature locator in a horizontal or slightly lower position This is dependent on the orientation of the splines as shown above Do not set higher as this will effect the...
Page 10: ...perature Maximum temperature Set horizontal or slightly higher Minimum temperature Maximum temperature button alignment button alignment button alignment Safe temperature button set to top suitable fo...
Page 11: ...ontrol handwheel A by unscrewing set screw B using a 1 5mm hexagonal key 2 Remove the override C and temperature stop D by unscrewing and removing screw E Fitting handwheel A and set screw B will aid...
Page 12: ...temperature by following the setting instruction in the setting safe temperature section Check the water temperature with a thermometer 1 Once the key setting points have been aligned and o rings L f...
Page 13: ...um screw N in a counterclockwise direction Gently pull the lever from the cartridge spline 2 Remove the cartridge cover P by unscrewing set screw Q using a 1 5mm hexagonal key We recommend wearing a r...
Page 14: ...thermostatic valve Unscrew the two collar nuts in a counterclockwise direction This will release the thermostatic valve from the mounting surface 3 Unscrew the elbow assemblies from the sides of the t...
Page 15: ...understands that the override control is to be returned to the safe temperature setting after use Hand these instructions along with the cleaning leaflet to the customer Ensure that the valve is suita...
Page 16: ...ct to licence or agreement with LBIP Ltd The design registrations trademark registrations and copyrights are protected by law and the use or reproduction outside the terms of an agreement is prohibite...