19
11.4
PRESET SPEEDS AND SPEED POT
(WITH TWO-WIRE START/STOP CONTROL)
NOTES:
1.
For preset speed control, all or some of the TB-13 terminals must be programmed as preset
speed selects. If only two or three preset speeds are required, only two of the TB-13 terminals
must be used. Refer to the table in the description of Parameters 31-37 in Section 15.0.
2.
Program the PRESET SPEEDS (Parameters 31-37) to the desired values.
3.
If speed pot control is desired when none of the preset speeds are selected (all preset speed
selects are open to TB-11), set STANDARD SPEED SOURCE (Parameter 05) to 0-10 VDC
(03).
1
2
5
6
11
13A
13B
13E
25
16
17
MAINTAINED
RUN/STOP
CONTACT
SPEED
POT
FORM A
RELAY
RUN
SIGNAL COMMON
0-10 VDC INPUT
SPEED POT POWER SUPPL
Y
DIGIT
AL INPUT REFERENCE
TB-13A FUNCTION SELECT
(PRESET SPEED #1)
TB-13B FUNCTION SELECT
(PRESET SPEED #2)
TB-13E FUNCTION SELECT
(PRESET SPEED #3)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]