Leesky LS-200L User Manual Download Page 2

LEESKY power inverter is an advanced tool of power conversion, and it can supply 

you  with  AC  power  converted  from  DC  power  source.  Not  only  can  be  used  in  cars, 
vessels and camping, but also can be used in emergency when out of electricity. 

B. Please read this instruction manual carefully and make sure your inverter is 

installed properly before using.

    In order to use the inverter efficiently and safely, please install and use it in a proper 
way. Please read the instruction carefully before installing and using the appliance.

A. INSTRUCTION

3) While connecting and using for the first time, if there is smoke or explosion sound 

in the product, please stop using immediately and disconnect the product from 
the battery and electrical appliances. This may be caused by damage during the 
transportation or due to moisture during storage in the warehouse before delivery. 
Please contact your seller in time.

2) While opening the product package, please check the integrity of the product and 

accessories. If there is any problem, please do not use it.

5) Do not put the inverter under direct sun light or near a heating source. 

4) During daily use, if there is smoke or explosion sound in the product, please don't 

worry, this is due to the internal fuse protection of the product. Please do not 
disassemble it by yourself. Please stop using the product immediately. 
Disconnect the product from the battery and electrical appliances. Contact the 
seller in time and only with seller's agreement a hired professional personnel can 
disassemble the product. Otherwise, it may cause electric shock, fire and serious 
personal injury.

1) Read the manual before connecting this inverter and keep it for future reference. 

C.  WARNING AND SAFETY

14) Keep the inverter well-ventilated. Do not place any objects on top of or next to the 

inverter or allow anything to cover the cooling fans; inverter will bel overheating, 
causing a potential fire hazard and/or damage to the inverter. Leave adequate 
ventilation space underneath the inverter as well; thick carpets or rugs can 
obstruct air flow, causing the inverter to overheat. 

13) People with pacemakers should consult their physician(s) before using this 

product. Electromagnetic fields in close proximity to a pacemaker could cause 
interference to or failure of the pacemaker. 

12) Do not operate the inverter if under the influence of alcohol or drugs. Read 

warning labels on prescriptions to determine if your judgement or reflexes are 
impaired while taking drugs. If there is any doubt, do not operate the inverter. 

11) Prevent body contact with grounded surfaces such as pipes, radiators, ranges, 

and refrigerator enclosures during installation. 

10) This device should only be serviced by a qualified technician. This item does not 

have any serviceable parts. 

9) Do not connect the negative to car chassis when use in car.

8) Do not disassemble the unit randomly: it may cause fire or electric shock. 

7) The power inverter is designed to be used with a negative ground electrical 

system! Don't use with positive ground electrical systems (the majority of modern 
automobiles, RVs, trucks and boats are negative ground). 

6) The case of inverter will get hot during using. Do not allow flammable materials 

such as clothing, sleeping bags, carpet or any other flammable materials to touch 
the inverter. The heat from the inverter can damage these items. 

1.

2.

D. FEATURES 

15) Avoid unintentional starting. Be sure the switch is in the OFF position when not in 

use and before plugging in any appliance. Disconnect the battery and inverter 
when not in use for a long time.

18) This product cannot be used for medical and life support equipment.

17) The power inverter will output the same AC power as utility power, please treat the 

AC  outlets as carefully as you would your home AC outlets. Do not put anything 
other than an electrical appliance into the output terminal. It may cause shock or 
fire. 

16) Keep inverter away from children. Don't install the inverter where it is accessible to 

children. 

 Data

Model

Output Wave Form

Output Power

Surge Power 

Output Voltage

Pure Sine Wave(THD

3%)

200W

400W

110-120VAC, 60Hz/220-240VAC, 50Hz 

(Refer to label)

1) Adopt advanced MPU control.

DC Input Voltage

Over Load power

Efficiency

No Load Current

Battery Low Alarm

Battery Low Shutdown

Input Over Voltage Shutdown

12V (9.5-16V) 

200W

About 90%

0.4A

DC 9.8  0.3V

±

DC 9.5  0.5V (Automatic Recovery at 12.5VDC)

±

DC16 0.5 V (Automatic Recovery at 14VDC)

±

Operating Temperature

(Automatic Recovery/Shutdown)

Over Temperature Protection

FAN Control Mode

32-113

°F

149

41

°F

°F

±

Load control (working while load more than 100W)

Support QC2.0/3.0;

Simultaneous using [email protected]

×

2;

Single using support [email protected], [email protected]

12V@2A

Type-A USB Output

Type-C USB Output

Internal DC Input Fuse

Power Switch

Cigarette Lighter Cable

Dimensions (LxWxH)

Net Weight

PD 30W Maximum, 2.4A@ 5V/9V/12V

Must Be Fitted, Use 30A Maximum

ON/OFF Control

YES

7”x 3.67” x 2.13”

1.6lb

Reviews: