![Leenders WALD Installation Manual Download Page 3](http://html1.mh-extra.com/html/leenders/wald/wald_installation-manual_1868036003.webp)
WALD
LEENDERS
2019.
49.002.I.EN
Points for special attention when installing the Wald
• Installation option 1, fixing with threaded ends and counter plate is recommended. This provides
the Wald with better side-collision protection.
• If the ceiling height exeeds 2750mm, the Wald can only be suspended according to option 1, with
the counter plate and threaded ends.
• The Wald can only be connected to an insulated double-walled flue.
• This stove appliance must be fitted to a ceiling that can easily support the load.
• The weight of the double-walled flue must not be supported by the connection to the Wald.
Poujoulat Efficience
• Can be connected to the Poujoulat Efficience to draw in fresh air through the flue. A special
connector is required for this and can be supplied with the stove if requested.
Art. nr. ENA15SP49.