Ledj STAGE WASH U.V. 36 LEDJ106 User Manual Download Page 3

 STAGE WASH U.V. 36 

 

 

 

                                                                      Safety

IMPORTANT:

           

The manufacturer will not accept liability for any resulting damages caused 

by the non-observance of this manual or any unauthorised modification to the

equipment.

 

• Never let the power-cable come into contact with other cables. Handle the power-cable 

 

  and all mains voltage connections with particular caution!

 

• Never remove warning or informative labels from the equipment.

 

• Do not open the equipment and do not modify the equipment.

 

• Do not connect this equipment to a dimmer-pack.

 

• Do not switch the equipment on and off in short intervals, as this will reduce the 

 

  system’s life.

 

• Only use the equipment indoors.

 

• Do not expose to flammable sources, liquids or gases.

 

• Always disconnect the power from the mains when equipment is not in use or before 

 

  cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the 

 

  power-cable.

 

• Make sure that the available voltage is between 220v/240v.

 

• Make sure that the power-cable is never crimped or damaged. Check the equipment and 

 

  the power-cable periodically.

 

• If the equipment is dropped or damaged, disconnect the mains power supply immediately. 

 

  Have a qualified engineer inspect the equipment before operating again.

 

• If the equipment has been exposed to drastic temperature fluctuation (e.g. after 

 

  transportation), do not switch it on immediately. The arising condensation might damage 

 

  the equipment. Leave the equipment switched off until it has reached room temperature.

 

• If your product fails to function correctly, discontinue use immediately. Pack the unit 

 

  securely (preferably in the original packing material), and return it to your Prolight dealer 

 

  for service.

 

• Only use fuses of same type and rating.

 

• Repairs, servicing and power connection must only be carried out by a qualified 

 

  technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS.

 

• WARRANTY; One year from date of purchase.

OPERATING DETERMINATIONS

If this equipment is operated in any other way, than those described in this manual,

the product may suffer damage and the warranty becomes void.

Incorrect operation may lead to danger e.g.: short-circuit, burns, electric shocks, 

lamp failure etc.

Do not endanger your own safety and the safety of others!

Incorrect installation or use can cause serious damage to people and property.

Summary of Contents for STAGE WASH U.V. 36 LEDJ106

Page 1: ...www prolight co uk STAGE WASH U V 36 order code LEDJ106 USER MANUAL ...

Page 2: ...ARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written i...

Page 3: ...ble periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has rea...

Page 4: ...oduction CONTROL FEATURES 2 channel DMX Blackout Dimmer Strobe Features 36 Ultra Bright 1W Ultra Violet LEDs Master Slave functions Sound activated Rugged compact housing Consumption 42W Beam 40 degrees Long life LEDs DMX Channel Summary ...

Page 5: ...36 is a DMX 512 controllable unit made up of high efficiency and super bright Ultra Violet LEDs The Stage Wash U V 36 will operate in stand alone Master Slave sound activated or via DMX 512 control LED Display Down Button Up Button DMX IN DMX OUT DMX IN DMX OUT DMX IN Mode Button Enter Button ...

Page 6: ...nd Mode To set the unit in sound mode press the mode button to show the last sensitivity setting between S 00 S 99 on the LED display Now press the ENTER button and use the UP and DOWN buttons to set the sound sensitivity level from 00 99 00 low 99 high DMX mode To set the unit in DMX mode press the mode button to show the last DMX address setting between A000 A255 on the LED display Now press the...

Page 7: ...st controllers only have a data out terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are co...

Page 8: ...oid erratic behaviour Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below de...

Page 9: ...Dimensions Length 300mm Width 255mm Height 125mm Weight 3 7 kgs Power AC input 240V 50hz Fuse Main 20mm Glass 2A Fast Blow Control Programming Data input Locking 3 pin XLR male socket Data output Locking 3 pin XLR female socket Protocols DMX 512 USITT DMX channels 2 ...