STAGE WASH U.V.
CONTROL OPTIONS
Manual Control Options
Dimmer
• With Dip Switch 1 only set to
ON
you obtain 25% output
• With Dip Switch 2 only set to
ON
you obtain 50% output
• With Dip Switches 1, 2 and 3 only set to
ON
you obtain 75% output
• With Dip Switches 1, 2, 3 and 4 only set to
ON
you obtain 100% output
Speed
Once you have selected the output power, you can vary the Speed by using the following:
• With Dip Switch 5 only set to
ON
you obtain minimum speed
• With Dip Switches 5 and 6 only set to
ON
you obtain medium speed
• With Dip Switches 5, 6 and 7 only set to
ON
you obtain fast speed
• With Dip Switches 5, 6, 7 and 8 only set to
ON
you obtain maximum speed
Blackout Mode
With only dip switch #10 + 1 set to
ON
the Stage Wash U.V. will blackout.
DMX Control Mode
Operating in a DMX control mode environment gives the user the greatest flexibility when it comes
to customising or creating a show. In this mode you will be able to control each individual trait of
the fixture and each fixture independently. The Stage Wash U.V. uses 2 channels of control.
Enable the DMX control by setting dip switch No: 10 to the
ON
position. Use dip switches 1 – 9 to
address each fixture accordingly.
Setting the DMX address
The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start
address” from 1- 511. A fixture requiring one or more channels for control begins to read the data
on the channel indicated by the start address. For example, a fixture that occupies or uses 7
channels of DMX and was addressed to start on DMX channel 100, would read data from
channels: 100,101,102,103,104,105 and 106. Choose a start address so that the channels used
do not overlap. E.g. the next unit in the chain starts at 107.