background image

DMX Linking: 

• DMX is a language allowing all makes and models of different manufactures to be linked together 

and operate from a single controller, as long as all fixtures and the controller are DMX compliant. 

To ensure proper DMX data transmission, when using several DMX fixtures try to use the 

shortest cable path possible. The order in which fixtures are connected in a DMX line does not 

influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be 

placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a 

fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to 

address 1 to that unit, no matter where it is located in the DMX chain.

DATA Cable (DMX cable) requirements (for DMX operation):

• The Slimline 229 can be controlled via DMX-512 protocol. The DMX address is set on the back of 

the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for data input/

output (figure 1). 

 

Also remember that DMX cable must be daisy chained and cannot be split.

Notice:  

• Be sure to follow figures 2 & 3 when making your own cables. Do not connect the cable’s shield 

conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer 

casing. Grounding the shield could cause a short circuit and erratic behaviour.

Special Note: Line termination:

      • When longer runs of cable are used, you may need to use a terminator on the last unit to 

        avoid erratic behaviour.

Using a cable terminator (part number CABL90) will decrease the possibilities of erratic 

behaviour. 

5-Pin XLR DMX Connectors:

     • Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-Pin 

       XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin 

       XLR connectors in to a 3-pin line a cable adaptor must be used. The Chart below details the 

       correct cable conversion.

 LEDJ Slimline 229 IR 

 

                                                                                   DMX Setup

Figure 1

Termination reduces signal transmission problems 
and interferance. it is always advisable to connect a 
DMX terminal, (resistance 120 Ohm 1/4 W) between 
pin 2 (DMX-) and pin 3 (DMX+) of the last fixture.

Summary of Contents for Slimline 229 IR

Page 1: ...w w w p r o l i g h t c o u k Slimline 229 IR Order code LEDJ51 USER MANUAL...

Page 2: ...E USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer an...

Page 3: ...able periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been...

Page 4: ...onal I R remote LEDJ90C Power consumption 20W Beam angle 25 degrees Dimensions 79 x 268 x 320mm Weight 2 5Kgs Operating modes 1 Static colour mix mode 2 Built in programmes 3 Slave mode 4 Sound active...

Page 5: ...its together using a 3 pin DMX cable then press the MODE button to select one of the above modes On the Slave units press the mode button until the LED display shows SLAV The Slave units will then fol...

Page 6: ...come on this now means that the second digit 4 tens place setting is successful 4 Now Press the 5 button and all of the R G B A W LEDs will come on this means that the final digit 5 units place setti...

Page 7: ...munication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fix...

Page 8: ...ata input output figure 1 Also remember that DMX cable must be daisy chained and cannot be split Notice Be sure to follow figures 2 3 when making your own cables Do not connect the cable s shield cond...

Reviews: