www.prolight.co.uk
Slimline Q5 Series
User Manual
6
RGBW colour mix mode:
In this mode you can set the fixture to any colour and any brightness.
To access the colour mix mode, press the
“MENU”
button on the rear of the unit to show
r---
with 3 digits after on the LED display. Press the
“ENTER”
button to confirm.
The
r
represents red,
G
= green,
b
= blue,
U
= white and
F--0
= strobe.
The 3 digits after are the brightness setting from
000
~
255
, or the strobe speed from
0
~
9
.
For example:
If you set
r
,
G
,
b
,
U
all to zero, your unit will have no LEDs lit up (blackout).
If you set
r000
to
r255
and
G
,
b
and
o
to zero, your unit will show only red LEDs.
Press the
“ENTER”
button to confirm the setting and move to the next colour.
To exit out of any of the above options, press the
“MENU”
button.
RGBA colour mix mode:
In this mode you can set the fixture to any colour and any brightness.
To access the colour mix mode, press the
“MENU”
button on the rear of the unit to show
r---
with 3 digits after on the LED display. Press the
“ENTER”
button to confirm.
The
r
represents red,
G
= green,
b
= blue,
A
= amber and
F--0
= strobe.
The 3 digits after are the brightness setting from
000
~
255
, or the strobe speed from
0
~
9
.
For example:
If you set
r
,
G
,
b
,
A
all to zero, your unit will have no LEDs lit up (blackout).
If you set
r000
to
r255
and
G
,
b
and
A
to zero, your unit will show only red LEDs.
Press the
“ENTER”
button to confirm the setting and move to the next colour.
To exit out of any of the above options, press the
“MENU”
button.
Built-in program mode:
To access built-in program mode press
“MENU”
until the display shows
Pr--
on the LED display.
Press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons to select between
Pr00
~
Pr20
.
Press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons to select the speed between
SP-0
~
Sp-9
. Press the
“ENTER”
button and use the
“UP”
and
“DOWN”
buttons to select the flash speed
between
F--0
~
F--9
.
To exit out of any of the above options, press the
“MENU”
button.
Slave mode:
Press the
“MENU”
button on the rear of the unit to show
SLAU
on the LED display and press the
“ENTER”
button to confirm the setting. The unit will now run in sequence with the master unit.
To exit out of any of the above options, press the
“MENU”
button.
Please ensure that all slave units are set to the same DMX channel mode as the master unit.
Operating instructions