background image

www.prolight.co.uk

150W COB CW/WW Par

  

User Manual

6

DMX mode:

Operating in a DMX control mode environment gives the user the greatest flexibility when it comes  
to customising or creating a show. In this mode you will be able to control each individual trait of  
the fixture and each fixture independently. 
To access the DMX address mode, press the 

“MENU”

 button on the rear of the unit to show  

d.001

 on 

the LED display. Now use the 

“UP”

 and 

“DOWN”

 buttons to set the required DMX address. Press the 

“ENTER”

 button to confirm the setting.

 

The DMX channel mode will now be displayed, use the 

“UP”

 and 

“DOWN”

 buttons on the rear of the unit to select either 2/3/4 or 6 DMX channel mode.  

Press the 

“ENTER”

 button to confirm the setting. The dimming curve settings will now be displayed, use 

the 

“UP”

 and 

“DOWN”

 buttons on the rear of the unit to select between 

dr-1

 ~ 

dr-4

.  

Press the 

“ENTER” 

button to confirm the setting.

To exit out of any of the above options, press the 

“MENU”

 button.

 

 

Operating instructions

Channel Value

Function

1

000-255 Cool White dimmer (0-100%)

2

000-255 Warm White dimmer (0-100%)

2 channel mode:

Channel Value

Function

1

000-255 Cool White dimmer (0-100%)

2

000-255 Warm White dimmer (0-100%)

3

000-020 Linear (dimming curve)
021-040 Square Law (dimming curve)
041-060 Inverse Square Law (dimming curve)
061-080 S-Curve (dimming curve)
081-255 Default dimming curve (set via menu)

3 channel mode:

Channel Value

Function

1

000-255 Cool White dimmer (0-100%)

2

000-255 Warm White dimmer (0-100%)

3

000-255 Master dimmer (0-100%)

4

000-020 Linear (dimming curve)
021-040 Square Law (dimming curve)
041-060 Inverse Square Law (dimming curve)
061-080 S-Curve (dimming curve)
081-255 Default dimming curve (set via menu)

4 channel mode:

Channel Value

Function

1

000-255 Cool White dimmer (0-100%)

2

000-255 Warm White dimmer (0-100%)

3

000

No function

001-255 Variable white (3200K-6400K)

4

000-015 No function
016-255 Strobe (slow-fast)

5

000-255 Master dimmer (0-100%)

6

000-020 Linear (dimming curve)
021-040 Square Law (dimming curve)
041-060 Inverse Square Law (dimming curve)
061-080 S-Curve (dimming curve)
081-255 Default dimming curve (set via menu)

6 channel mode:

dr-3

 - Inverse Square Law

dr-4

 - S-curve

dr-1

 - Linear

dr-2

 - Square Law

Summary of Contents for 150W COB RGBA Par

Page 1: ...Order code LEDJ375 150W COB CW WW Par User Manual...

Page 2: ...in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is...

Page 3: ...ied with three beam reduction lenses 25 40 and 50 which are easily interchangeable The 4 button DMX display allows access of built in colour macros 4 selectable dimmer curves 0 100 electronic dimming...

Page 4: ...put 11 Fuse T3A 250V 12 Hanging bracket 13 Hanging bracket adjustable knob In the box 1 x fixture 1 x 25 beam reduction lens 1 x 40 beam reduction lens 1 x 50 beam reduction lens 1 x power cable 1 x u...

Page 5: ...F F Display backlight S t n d r E v Display inverse d E F A Reset factory settings h 0 0 0 h 2 5 5 C 0 0 0 C 2 5 5 F 5 0 0 F 5 1 5 Manual dimming mode h 2 5 5 C L 0 0 C L 0 8 F 5 0 0 F 5 1 5 Static c...

Page 6: ...Value Function 1 000 255 Cool White dimmer 0 100 2 000 255 Warm White dimmer 0 100 2 channel mode Channel Value Function 1 000 255 Cool White dimmer 0 100 2 000 255 Warm White dimmer 0 100 3 000 020...

Page 7: ...ue 000 255 000 low brightness 255 high brightness Value 00 15 00 no flash 15 fast flash speed To exit out of any of the above options press the MENU button Static colour To access the static colour mo...

Page 8: ...To reset the factory settings press the MENU button until the display shows don on the LED display Press the ENTER button twice to display dEFa Press the UP and DOWN buttons together and the fixture w...

Page 9: ...DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To en...

Page 10: ...5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin...

Page 11: ...ssible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material...

Page 12: ...www prolight co uk 150W COB CW WW Par User Manual 12...

Reviews: