Ledino
LED LIGHTING
the energy saving company
220-240V/AC, 50/60Hz
HF system: 5.8 GHz, transmission power: < 0.2 mW*
Switched power: max. 1200 W tungsten lamp, LED (cosφ=1)
max. 300 W fluorescent lamp (cosφ=0.5)
Temperature range: -15 °C up to 70 °C
Power consumption: ca. 0,5 W
*) 0.2 mW is 1/5000 of the output power of a mobil phone
Installation height: 2,5 -3,5 m
Detection range: Ø 2-16 m
Time adjusting: 8 sec.-12 min.
Twilight switch adjusting: 2-2000 lx
The Ledino device is equipped with a high frequency sensor, also called microwave
sensor. Contrary to infrared sensors which react to heat differences, HF sensors work
like a radar.
- HF sensor can be mounted hidden – penetrates glass, wood and lightweight walls.
- The HF sensor can be used in environment with wide temperature range and dust
pollution.
- The HF sensor can be used for control security system (CCTV).
- The HF sensor works very reliable, the error rate is extremely low.
LED-MWS16360R
Ledino HF motion sensor
with twilight switch
IMPORTANT:
Read all instructions carefully. If you do not understand this instruction, contact your dealer. Check the device for transport
damage. Those has to be reported to the forwarder/carrier.
SAFETY:
Danger to life! The wiring must run according to local statutory regulations and guidelines.
All work must be carried out only by a qualified electrician.
Do not install the sensor in wet, damp or very hot areas.
Before drilling, make sure that no power, water or gas lines are present where the sensor is to be mounted.
WARNING:
Disconnect power during installation and before servicing. These procedures should only be performed by a qualified elec-
trician. Supply power should be turned off when replacing components or checking connections. Never perform mainte-
nance or cleaning while electric tension is not de-energized.
For your own protection, please wear protective goggle and dust mask.
96.00mm
42.00mm
Fig. 5
Fig. 6
Fig. 7
base hole
electrical load
(lamp, camera,....)
L
L
N
N
N
L‘
L
Fig. 8
Fig. 4
Fig. 3
Fig. 2
Fig. 1
Installation
1. Take down the top cover by turning it anti-clockwise
see fig 1
.
2. Tighten off the two screws fixing middle cover
see fig 2
.
3. Hold base against the ceiling and mark drill holes
see fig 3
.
4. Drill the holes (Ø 6 mm)
see fig 4
.
5. Insert the dowel
see fig 5
.
6. Put wires through the base hole and connect the wires
according the marks
see fig 6+7
.
7. Fixed the base with 2 screws and fasten the middle cover with
the screws and screw on the top cover clockwise
see fig 8
.
220-240 V/AC
50/60 Hz