Connect wire according to circuit diagram 

electrical load

(lamp, camera,....)

N

N

220-240 V/AC

 50/60 Hz

L

L

N

L‘

L

Installation

It can be installed inside of products (e. g. ceiling lamps) that is made of glass and plastic.

The sensor can be placed also in false ceilings (plasterboard, wood).

Test the performance of the sensor before final installation, whether it really sufficiently penetrate the material for 

your purposes. Metal plates and foils insulate the sensor completely.

Ledino

 

LED LIGHTING

the energy saving company

220-240V/AC, 50/60Hz

HF system: 5.8 GHz, transmission power: < 0.2 mW* 

Switched power: max. 1200 W tungsten lamp, LED (cosφ=1)

                                 max. 300 W fluorescent lamp (cosφ=0.5)

Temperature range: -15 °C up to 70 °C

Power consumption: ca. 0,5 W

*) 0.2 mW is 1/5000 of the output power of a mobil phone

Installation height: 2,5 -3,5 m

Detection range: Ø 2-16 m

Time adjusting: 8 sec.-12 min.

Twilight switch adjusting: 2-2000 lx

The Ledino device is equipped with a high frequency sensor, also called microwave 
sensor. Contrary to infrared sensors which react to heat differences, HF sensors work 
like a radar. 
-  HF sensor can be mounted hidden – penetrates glass, wood and lightweight walls.
- The HF sensor can be used in environment with wide temperature range and dust  
  pollution.
- The HF sensor can be used for control security system (CCTV).
- The HF sensor works very reliable, the error rate is extremely low.

LED-MWS16360

Ledino HF motion sensor  

with twilight switch

IMPORTANT:

Read all instructions carefully. If you do not understand this instruction, contact your dealer. Check the device for transport 

damage. Those has to be reported to the forwarder/carrier.

      SAFETY:

Danger to life! The wiring must run according to local statutory regulations and guidelines.

All work must be carried out only by a qualified electrician.

Do not install the sensor in wet, damp or very hot areas.

Before drilling, make sure that no power, water or gas lines are present where the sensor is to be mounted. 

      WARNING:

Disconnect power during installation and before servicing. These procedures should only be performed by a qualified elec-

trician. Supply power should be turned off when replacing components or checking connections. Never perform mainte-

nance or cleaning while electric tension is not de-energized.

For your own protection, please wear protective goggle and dust mask.