Leding Razer 440 User Manual Download Page 4

2

   Never let the power-cord come into contact with other cables! Handle the power cord and all connections 
with particular caution!
   Make sure that the available voltage is not higher than stated on the rearpanel.
   Always plug in the power plug least. Make suer that the power-switch is set to off-position before you con
ections with themains with particular caution!
   Make sure that the power-cord is never crimped or damaged by sharp edges.Check the decice and the p-
ower-cord from time to time.
    Always disconnect from the mains, when the device is not in use or before cleaning it.
    Only  handle the power-cord by the plug,Never pull out the plug by tugging the powercord.
    This  device falls under protection class I.Therefore it is essential to connect the yellow/green conductor
to earth.
    The  electric connection,repairs and servicing must be carried out by a qualified employee.
    Do  not connect this device to a dimmer pack.
    Do  not switch the fixture on and off in short intervals as this would reduce the lamp’s life.
   Do not touch the device’s housing bare hands during its operation(housing becomes hot)!
   For replacement use lamps and fuses of same type and rating only.
  

t  80

c

°

C

IP20

t  40

a

°

C

Eye damage!

Avoid looking directly into the light source(meant especially for epileptics)!

Minimum

 

distance

 

of

 

illuminated

 

objects

18 metres from

 

the lens of the projector.

Maximum

 

ambient

 

temperature

Do not operate the fixture if the ambient temperatuer(Ta) exceeds 40

°

C (104

°

F).

Temperature of the external surface

The maximum temperature that can be reached on the external surface of the fitting,in a ther-
mally steadystate

,

is 80

°

C (176

°

F).

IP20

 

protection

 

rating

The fitting is protected

 

against

 

penetration by solid of over 12mm

 (

0.47

”) 

in

 

diameter

 (

first

digit 2), but

 

not

 

against dripping water,rain,splashes or jets of water (second digit 0).

Indoor use only

Not suitable for household illumination

Photobiological

 

Safety

CAUTION. Do not look directly at the light source.Do not look at the light beam with optical de-
vices or any other tool that could cause light convergence.
The fixture must be positioned so that the minimum distance between the front lens and human
eye is at least 3metres to prevent personal photobiological risks.

Mounting  surfaces

It is permissible to mount the fitting on normally flammable surfaces.

The products to which this manual refers comply with the European Directives  purs-
uant to

:

2006/95/EC - Safety

 

of

 

electrical

 

equipment

 

supplied

 

at

 

low

 

voltage

 (

LVD

)

2004/108/EC - Electromagnetic Compatibility (EMC)

2011/65/EU - Restriction of the use of certain hazardous substances (RoHS)

2009/125/EC - EcoDesign requirements for Energy-related Products (ErP)

Protection

 

against electrical shock

Connection must be made to a power supply system fitted with efficient earthing (Class I app-
liance according to standard EN 60598-1) .It is, moreover, recommended to protect the supply

The projector needs to be positioned  so that the objects hit by the  beam of  light  are at  least 

F

Risk Group 1

According to
    En62471

2.5m

750W

Summary of Contents for Razer 440

Page 1: ...Razer 440 USER MANUAL...

Page 2: ...Electrical paramters 15 10 2 10 3 10 5 light table 16 10 7 18 11 Electronic drawing 19 4 2Installing the Clamps 4 4 3 Power supply connection and cut off 5 4 4 POWER Connection 6 4 5 DMX 512 connecti...

Page 3: ...ernation 512 agreement keep it ation of this pro instruction teris tic with standard of DMX 1 Signal cable 1PC 2 Safty cable 1PC 3 User Manval 1PC 4 Omega holder 2PCS 5 Power cable 1PC 5 Service card...

Page 4: ...ixture if the ambient temperatuer Ta exceeds 40 C 104 F Temperature of the external surface The maximum temperature that can be reached on the external surface of the fitting in a ther mally steadysta...

Page 5: ...er life the fixture by holding it at the projectorhead as the mechanics may be damaged Always hold the fixtu re at the transport handles When choosing the installation spot please make sure that the d...

Page 6: ...e first time and after changes before taking into operation an other time The operator has to make sure that safety relating and machine technical installations are approved by an expert after every f...

Page 7: ...ussing system etc 1 2 3 4 Warning it is necessary to make sure that the installation location is perfectly appropriate and the installation location is safe and reliable mounting plate secure chain om...

Page 8: ...he last fixture the DMX cable has to be terminated with a terminatou solder a 120 resistor between signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture DMX iutput...

Page 9: ...an XLR plug witha 120 resistor connected between pins 2 and pins3 which is then plugged into a the output XLR socket of the last ifxture in the chain 1 2 3 120 PIN2 PIN3 CINTROL PANEL 4 3 5 Power in 6...

Page 10: ...8 17 6 Dimension 17 WDMX wire...

Page 11: ...o view the software version press the UP DOWN can m odify the DMX address If the screen icon is green said DMX signal connection is normal this state can be used to check th elamps and lanterns and co...

Page 12: ...E042 B Fan1 Error E044 B Fan2 Error E053 L Fan1 Error E055 L Fan2 Error Check the fan of head Check if the fan 80 of the lamp holder is working Check the light coupling line optical coupling switch a...

Page 13: ...Wired Input Wired Input defaul Wireless Input Wireless Input Wireless In XLR out Wireless In XLR out English Chinese Brightness Brightness Screen Time out 0 10m Screen Time out Touch Screen ON OFF Tou...

Page 14: ...op 214 219 CCW slow or fast 220 243 Random slow color 244 247 Random medium color 248 251 Random fast color 252 255 6 3 4 Cyan Linear Cyan movement 0 255 7 4 5 Magenta Linear Magenta movement 0 255 8...

Page 15: ...2 Forwards Prism rotation from fast to slow 3 126 No rotation 127 129 Backwards Prism rotation from slow to fast 130 253 No rotation 254 255 16 14 15 Frost Focus moves linearly into the light beam 0 2...

Page 16: ...Complete 3 sec 10 14 Reset CMY CTO and color wheel only 3 sec 15 19 Reset Other 3 sec 20 24 Reset Pan Tilt 3 sec 25 29 Reset Gobo 3 sec 30 34 Dimmer Curve 1 linear 1 sec 35 39 Dimmer Curve 2 Gamma1 5...

Page 17: ...he fine wire fuse of the device might fuse too Only replace the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Maintenance and maintenance of the operation please c...

Page 18: ...ch on and off the lamp via the control panel or via your DMX controller It must be noted that it has to be cold before re stricking 6 After the DMX signal is disconnected the display will be bright an...

Page 19: ...Rgobo wheel Glass design Inside diameter34 7mm effective diameter 30mm 10 6 Gobo wheel Integra Inside diameter 162mm effective diameter 25 5mm Integra Inside diameter mm effective diameter 124mm 130...

Page 20: ...18 10 7 Color wheel CTO Magnets Pink blue red Green orange Fluorescent...

Page 21: ...EN Titl Sensor Pan Sensor L N Three Phase Motor Driver Board L G LED Fan F2 LED Fan F1 LED Control Cyan Magnta Yellow Static Gobo Wheel M1 M2 M3 M4 M5 M6 M7 M8 YM MM Magnta CM GM M1 M2 M3 M4 M5 M6 M7...

Page 22: ......

Reviews: