background image

O P E R A T I O N   M A N U A L

3

301 Thor Place, Brea, CA 92821 | 

tel

 (714) 256-2111 | 

fax

 (714) 256-2118 | [email protected]

www.ledconn.com 

Specifications are subject to change without notice. © 2020 LEDCONN CORP. All Rights Reserved.

OM.20.01.R0

LUXDA ZZLE

Dynamic Motion Lighting

RGB

Summary of Contents for LUXDAZZLE MC100 SYSTEM

Page 1: ...R A T I O N M A N U A L 301 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledconn com www ledconn com Specifications are subject to change without notice 2020 LEDCONN CORP All Rights Reserved OM 20 01 R0 LUXDAZZLE Dynamic Motion Lighting RGB ...

Page 2: ...100_220_Setup in the folder and install it as shown below 301 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledconn com www ledconn com Specifications are subject to change without notice 2020 LEDCONN CORP All Rights Reserved OM 20 01 R0 LUXDAZZLE Dynamic Motion Lighting RGB ...

Page 3: ...01 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledconn com www ledconn com Specifications are subject to change without notice 2020 LEDCONN CORP All Rights Reserved OM 20 01 R0 LUXDAZZLE Dynamic Motion Lighting RGB ...

Page 4: ...ace to connect computer Power supply Optional customer can prepare by self 1 1 1 1 2 2 301 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledconn com www ledconn com Specifications are subject to change without notice 2020 LEDCONN CORP All Rights Reserved OM 20 01 R0 LUXDAZZLE Dynamic Motion Lighting RGB ...

Page 5: ... and output the red light on and the green light flashing when the connection is correct connect by data cable Indicator Output interface 301 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledconn com www ledconn com Specifications are subject to change without notice 2020 LEDCONN CORP All Rights Reserved OM 20 01 R0 LUXDAZZLE Dynamic Motion Lighting RGB ...

Page 6: ...power for the light panel and receiving card 5V output positive 5V output negative AC input 301 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledconn com www ledconn com Specifications are subject to change without notice 2020 LEDCONN CORP All Rights Reserved OM 20 01 R0 LUXDAZZLE Dynamic Motion Lighting RGB ...

Page 7: ...al indicator will light up if the connection is correct Connection of the control box and receiving card Power indicator Signal indicator 301 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledconn com www ledconn com Specifications are subject to change without notice 2020 LEDCONN CORP All Rights Reserved OM 20 01 R0 LUXDAZZLE Dynamic Motion Lighting RGB ...

Page 8: ...5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5V Power supply 200W 5...

Page 9: ...ng from the front of the light box The right 8 columns of light panels are controlled by the receiving card 1 and the left 8 columns of the light panels are controlled by the receiving card 2 Total power of the light panels must be lower than the power output of the power supply Do not connect more than TWO pieces of light panels in series of each row More details please refer to User Manual of MC...

Page 10: ...x STEP2 Click Start Connection button make sure the main control box and receiving card are powered as in Figure 1 and then it will show the screen as Figure 2 301 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledconn com www ledconn com Specifications are subject to change without notice 2020 LEDCONN CORP All Rights Reserved OM 20 01 R0 LUXDAZZLE Dynamic Motion Lighting RGB ...

Page 11: ...Height as shown in Figure 4 2 Here takes the light box with 16 columns and 12 rows as an example for the LED quantities in each light panel are 16X16 so the width here is 16X16 256 and the height is 16X12 19 Click Save after setting Click Apply in Figure 3 4 Figure 3 1 Figure 3 2 Figure 3 3 Figure 4 1 Figure 3 4 Figure 4 2 301 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledcon...

Page 12: ...ure 6 3 did not show after clicking Find Receiver you could check the line connection first The red indicator on and the green indicator flashing means the right line connection Green indicator is not on which means line fault Figure 6 1 Figure 5 1 Figure 6 3 NOTE Figure 6 2 301 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledconn com www ledconn com Specifications are subject ...

Page 13: ...th is 128 and the height is 192 In this example the receiving card is left and right arranged so select Series Connection as Horizontal the number 1 and 2 in red color indicating the position of receiving card and 1 refers to the first receiving card and 2 for the second one Click Send Receiver Connection to OUT1 after all settings are done seeing Figure 7 6 and then close the window As the habit ...

Page 14: ... Figure 8 3 Import the HUB file contained in parent folder as Figure 8 4 Click Load from File button to import the file BV RGB NF230 hub as shown in Figure 8 5 Click Yes button in Figure 8 3 to show the screen of Figure 8 4 301 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledconn com www ledconn com Specifications are subject to change without notice 2020 LEDCONN CORP All Right...

Page 15: ...igure 8 7 click Close to finish Method 1 Network Cable Upload STEP 1 Set the size of display window Click Set Display Window Size to show the screen as Figure 9 2 and set the actual size of lightbox in Width and Height details refer to Step 4 then click OK Effects Settings 06 301 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledconn com www ledconn com Specifications are subject...

Page 16: ...m page Click Full Screen button to set the file videos pictures etc to full screen The Width and Height in red circle will be the same size of lightbox then Then set the program according to Figure 10 5 Figure 10 5 Figure 10 6 Click the Icon in red box to select the file to be used and open it to show the screen of Figure 10 6 Select Document effects still sliding in left or right side and set the...

Page 17: ...that comes with the MC100 control system showing in figure 10 9 STEP 3 Uploading of program refers to the Figure 10 7 and 10 8 STEP 1 Connect computer and MC100 control system STEP 2 Add programs and set the size of display window same as the Method 1 Method 2 WIFI Upload 301 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledconn com www ledconn com Specifications are subject to ...

Page 18: ...w below Click the Start upload in the red box showing in the Figure 10 13 It will show message Succeed to set default program after uploading succeed then close the Program Management page STEP 3 Uploading of programs Figure 10 10 Figure 10 11 Figure 10 12 Figure 10 13 301 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledconn com www ledconn com Specifications are subject to cha...

Page 19: ... be popped up after that then insert the USB drive into the USB port of the control box and the program will be uploaded automatically STEP 1 Set programs and the size of display window after open the MC100 software same as the Method 1 STEP 2 Uploading of programs Figure 10 14 Figure 10 15 Figure 10 16 301 Thor Place Brea CA 92821 tel 714 256 2111 fax 714 256 2118 sales ledconn com www ledconn co...

Reviews: