background image

www

.

LED

tronic

s

.c

om

SLL003P-400-xxx-x04 

SLL003P-800-xxx-x04 

SLL003P-35X2W-xxx-005    

SLL003P-70X2W-xxx-005  SLL003P-4X60W-xxx-005

Installation 

Instructions

PACKAGE INCLUDES: Lum Installation Instru Mounting Brackets (packed separately)

®

© 2010 LEDtronics, Inc.

23105 Kashiwa Court, Torrance, CA 90505

Phone:

 (800) 579.4875 / (310) 534.1505

Fax:

 (310) 534.1424

E-mail:

 [email protected]

Website:

 http://www.ledtronics.com

LED

TRONICS, INC.

®

THE FUTURE OF LIGHT

9001:2000

ISO

CERTIFIED by DNV

       READ AND FOLLOW ALL PRECAUTIONS AND INSTALLATION INSTRUCTIONS PRIOR TO INSTALLING LUMINAIRE

LED

TRONICS, INC.

®

THE FUTURE OF LIGHT

I

mportant 

S

afety 

I

nstructions

CAUTION 

 

– RISK OF ELECTRIC SHOCK.

 

Suitable for wet or damp locations.

To prevent wiring damage or abrasion, 

 

do not

 expose wiring to edges of sheet 

metal or other sharp objects.

CAUTION – RISK OF FIRE. 

 

This product must be installed in 

accordance with the applicable 

installation code by a person familiar 

with the construction and operation of 

the product and the hazards involved.

Consult a qualified electrician to ensure 

 

correct branch circuit conductor.

Save these instructions and deliver to 

 

owner after installation.

No user-serviceable parts inside.

 

INSTR-SLL003P

-0001-E / R

ev

. 02/2011

REMOVE PARTS

1. 

 

Remove 4 screws from the lens cover 

to remove it from the back enclosure 

(Figure 1). 

Remove 4 screws to take out cluster 

assembly from back enclosure (Figure 2).

KNOCK OUT / DRILL

2. 

 

Use provided knockouts for mounting 

or drill holes into back enclosure as 

necessary.

MOUNTING 

Line up the back enclosure in the 

desired location. 

Mount securely with the customer-

provided screws.

REASSEMBLE LUMINAIRE

3. 

 

Use 4 screws to reinstall the cluster 

assembly to the back enclosure (Figure 

1). 

Use 4 screws to attach the lens cover 

to the back enclosure (Figure 2).

Flush Mount Installation

HAVE NEEDED ITEMS HANDY:

1. 

 

Phillips screwdriver 

Slotted screwdriver 

Wrench 

Sealing material (wet 

locations)

 

Wire cutter/Strippers 

Twist-on wire connector (Wire 

nuts)

BRACKET OR FLUSH MOUNT

2. 

 

To install the bracket, follow 

the specific bracket installation 

instructions on pp. 2-3, and 

return to these instructions for 

wiring. 

To install by flush mount, 

follow the specific installation 

instructions below, and return to 

these instructions for wiring.
 

3. 

WIRING

 

Ensure all power is OFF before 

proceeding with wiring. 

If needed, strip supply wires. 

Use customer-provided 

twist-on wire connectors (wire 

nuts) for connection of supply 

wires to luminaire wires. Connect 

the black wire from fixture to the 

appropriate black supply wire 

(hot). Connect the white wire 

from fixture to the white supply 

wire (common). Attach the 

ground supply wire to the green 

ground wire. 

Dress wires away from sharp 

edges.
For wet locations, install to avoid 

4. 

water entering or accumulating 

in wiring compartments or other 

electrical parts. Use sealing 

material as needed. 
Turn power on.

5. 

Figur
e 2

SCREW 

WASHER 

(4 PLCS)

On Both 

Sides

CLUSTER

ASSEMBLY

Figur
e 1

WASHER

LENS COVER

#10-32 x 1” SCREW

1 SCREW 

AT EACH 

CORNER

O-RING

SEALING 

WASHER