background image

 Pro White LED Matrix Block 

 

      

 

                                                  DMX Set up

DMX-512: 

• DMX (Digital Multiplex) is a universal protocol used as a form of communication between 

  intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the 

  controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the 

  DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only   

  have a data “out” terminal).

DMX Linking: 

• DMX is a language allowing all makes and models of different manufactures to be linked together   

  and operate from a single controller, as long as all fixtures and the controller are DMX compliant.   

  To ensure proper DMX data transmission, when using several DMX fixtures try to use the 

  shortest cable path possible. The order in which fixtures are connected in a DMX line does not   

  influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be  

  placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a   

  fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to 

  address 1 to that unit, no matter where it is located in the DMX chain.

DATA Cable (DMX cable) requirements (for DMX operation):

• The Pro White LED Matrix Block can be controlled via DMX-512 protocol. The DMX address is 

  set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR 

  connector for data input/output (figure 1). 

 

Figure 1

Also remember that DMX cable must be daisy chained and cannot be split.

 

Further DMX cables can be purchased 

from all good sound and lighting suppliers 

or Prolight dealers.

Please quote:

 

CABL10 – 2M

 

CABL11 – 5M

 

CABL12 – 10M

8.

Summary of Contents for LEDJ231

Page 1: ...www prolight co uk Order code LEDJ231 USER MANUAL ...

Page 2: ...SING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in thi...

Page 3: ...r cable periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has...

Page 4: ...nels 3 16 or 19 selectable 16 x 20W White LEDs 3200K Sound active auto master slave and DMX modes Individually addressable LEDs 400Hz refresh rate Powercon in out sockets 3 Pin XLR in out sockets 5 Pin XLR in out sockets 4 push button menu with LCD display 0 100 dimming and variable strobe Beam angle 80 degrees Power consumption 348W Power supply 100 240V 50 60Hz Dimensions 180 x 425 x 400mm Weigh...

Page 5: ...he slave units will now run in sequence with the master unit Built in programmes To activate the units built in programmes press the MODE button to show 01 STATIC on the LCD screen Press the SET UP button to choose between the 14 built in programmes by using the UP and DOWN buttons Now press the SET UP button to select the desired speed and adjust by using the UP and DOWN buttons Press the SET UP ...

Page 6: ...Pro White LED Matrix Block Built in Programme Chart 15 Built in programme chart 5 ...

Page 7: ...8 95 Spot 11 96 103 Spot 12 104 111 Spot 13 112 119 Spot 14 120 127 Spot 15 128 135 Spot 16 136 143 Dream 144 151 Meteor 152 159 Fade 160 167 Change 168 175 Flow1 176 183 Flow2 184 191 Flow3 192 199 Flow4 200 207 Flow5 208 215 Flow6 216 223 Flow7 224 231 Flow8 232 239 Flow9 240 247 Flow10 248 255 Sound control Master Dimmer 0 100 Dimmer 0 255 Speed 0 255 Sensitivity 0 255 Flash 0 255 CH1 CH2 CH3 A...

Page 8: ...ode DMX chart 19 channel mode DMX chart Pro White LED Matrix Block DMX Programme Charts CH1 Spot 1 CH2 Spot 2 CH3 Spot 3 CH4 Spot 4 CH5 Spot 5 CH6 Spot 6 CH7 Spot 7 CH8 Spot 8 CH9 Spot 9 CH10 Spot 10 CH16 Spot 16 7 ...

Page 9: ...shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter wher...

Page 10: ... terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The chart below details the correct cable conversion ...

Page 11: ...10 ...