Lectranator Systems DIG60 Installation And Operation Manual Download Page 8

Section 2b 

– INSTALLATION 

 

 

Control Box Connections 

 

Electrical Connections 

Autopilot recommends that a licensed electrician or certified electrical contractor perform the electrical connections.  

DANGER: ensure that the electrical panel or filter pump circuit breaker is turned OFF before wiring this unit.  

Your 

Lectranator Digital Model DIG60 

Control Box comes pre-wired from the factory for 230VAC (1.5 amps max draw) and can also 

operate on 115 VAC, (3.0 amps max draw) at 50/60Hz. 1.8 m (6 ft.) of AC lead wires are provided with the unit and are  
located on the bottom base plate of the control box along with the Cell, Tri -Sensor and optional ORP Interface connections. 

Converting to 115VAC 

is accomplished by accessing the circuit board, rewiring, and attaching the included jumper as shown 

below. Remove the cover (see page 12) to access and ensure that the Jumper Connections on the circuit board marked 
“TRANSFORMER PRIMARY” are matched to the LINE IN voltage. Follow all state/local codes for electrical installations. 

 

?  An additional jumper is 

Power Circuit Board 

provided with your 
Installation Kit for 115VAC. 

Transformer 

Location of the 
Input Jumper Connections 

 

230 VAC 

 

115 VAC 

INNER CONTROL PANEL 

FACTORY SETTING 

WIRING DIAGRAM 

Top terminals factory wired – do not disturb. 

AC to PCB 

 

 

AC Line OUT 
to Filter Pump 

AC Line IN 

for Filter Pump 

Bonding 

Lug 

6-pin Tri-sensor 

 

#1 #2 #3 #4 #5 #6 

Pump 

Relay trigger 

Ground 

Ground 

Conduit 

Lugs 

Lug 

(to Low Speed)  connector 

Internal Relay 

provided 

(Gr/Yel) (Br) (Bl) 

Pump Ground Lug 

Pump conduit 

2-pin ORP 

 
 

Cell Cord 

Lectranator Digital Model DIG60 

AC Line IN 

Load wires out to Single Speed Pump 

Plugs 

Connector Connectors 

(or Brown to High Speed) 

 

CONTROL BOX BASE PLATE 

Pump AC Line IN 

Pump AC Line OUT 

AC LINE IN 

(Wiring diagram also located on inside of cover)

For 230 VAC

; Brown (Br) = Line 1, Blue (Bl) = Line 2, Green w/Yellow Tracer (Gr/Yel) = Earth Ground  

For 115 VAC

; Brown (Br) = Line, Blue (Bl) = Neutral, Green w/Yellow tracer (Gr/Yel) = Earth Ground  

The AC Line IN wiring is pre-set for connection to the 

LOAD SIDE 

of your time clock, electronic controller switch or relay to 

work in conjunction with your circulation pump. 
For control of your main circulation pump (single or two speed) through the 

Lectranator Digital Model DIG60

’s 

Internal Relay, cut and 

strip the pre-wired Line In wires, and jump #1 to #3 and #2 to #4 (Gr/Yel can be discarded).  Route a new set of Pump AC Line IN 
wires from the circuit breaker/electrical panel into #3, #4 and Pump Ground Lug. Connect Pump AC Line OUT to #5, #6  and 
Pump Ground Lug.  This relay is rated for 30-amp max.  Ensure that the Line In and Line Out wire sizes are according to  
electrical guidelines. Follow the menu program, pages 8 & 9, to program the 

Digital 

to your particular application. Ensure 

that the 

Lectranator Digital Model DIG60 

Control Box is properly bonded to a grounding circuit. 

Cell Cord

Each Cell Cord contains (2) Banana Plugs that attach to the (2) Banana Jacks on the bottom of the Control Box. 

Polarity does not matter. The other end of the cell cord has a three -position plug that connects to the cell in any direction. See 
page 13 for service instructions. 

Tri-Sensor Cord

The Tri-Sensor Cord connects to the keyed 6-pin harness on the Control Box Base Plate. The opposite 

end of the cord connects to the Tri-Sensor Assembly with a locking ring quick connect. Align the grove and keyway on th e 
connector and twist the locking ring to ensure a proper connection. Refer to the instructions on pages 12 & 14 for diagrams 
and additional instructions. 

ORP Connection

When an ORP Chemical Controller is interfaced to your 

Lectranator Digital Model DIG60

, the Chemical 

Controller will remotely control the sanitizer Output. Adjust the output level to 0% and connect the ORP controller to the 2-pin 
connector on the Control Box Base Plate.  When the ORP is activated, the output will indicate ON with the display showing 0%. 

WARNING: THE ORP CONNECTIONS ARE DRY CONTACT INPUTS, DO NOT ENERGIZE THESE 

INPUTS! DAMAGE TO THE CONTROL BOX WILL OCCUR AND WILL VOID THE WARRANTY.  

connector 

TRANSFORMER PRIMARY 

TAB 4 

TAB 3 

115VAC 

TAB 6 

TAB 5 

TAB 8 

TAB 7 

115VAC 

TAB 10 

TAB 9 

TRANSFORMER PRIMARY 

TAB 4 

TAB 3 

TAB 6 

TAB 5 

230VAC 

TAB 8 

TAB 7 

TAB 10 

TAB 9 

AC 

Plug 

Line In 

Plug 

Summary of Contents for DIG60

Page 1: ...e gases which can result in FIRE OR EXPLOSION DOMESTIC READ THE LABEL AND THE INSTALLATION AND OPERATION MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN Imported to Canada by LECTRANATOR SYSTEMS INC 1034 72 Avenue N E Calgary Alberta T2E8V9 Phone 1 866 517 7584 REGISTRATION NO 27843 PEST CONTROL PRODUCTS ACT LECTRANATOR DIGITAL MODEL DIG60 Chlorine or Bromine Generating One DIG60 unit can treat ...

Page 2: ... CONTROL PRODUCTS ACT and Lectranator Digital Model DIG60 REGISTRATION NUMBER 27843 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine or bromine generating device Read the Label and the Installation and Operation Manual of the chlorine or bromine generating device Lectranator Soft Touch Model ST60 or Lectranator Digital Model DIG 60 before using Lectranator Systems ...

Page 3: ...s Bacteria And Algae In Swimming Pool Waters For Indoor or Outdoor Use RETAIN MANUAL FOR FUTURE REFERENCE C NSF50 IMPORTANT READ THE LABEL AND THIS MANUAL BEFORE INSTALLING OPERATING Notice to User This pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Product Act to use this product in a way that is inconsistent with the...

Page 4: ...TLINE 1 866 517 7584 or 1 403 291 9845 FAX 1 403 291 1023 Visit Us On The Internet www lectranator com Manufactured for Lectranator Systems Inc 1034 72 Avenue N E Calgary Alberta Canada T2E 8V9 Lectranator Digital Model DIG60 by LECTRANATOR SYSTEMS INC Model RC 13 Serial Number Cell Cell Model Number DIG60 Serial Number Control Unit Control Unit Installer Date of Installation ...

Page 5: ...e with manufacturer s instructions 6 DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times Children should not use spas hot tubs or pools without permanent adultsupervision Equipment Related 115 230VAC 50 60 Hz Models fixed wiring 1 A wire connector is provided on your Lectranator Digital Model DIG60 to connect a minimum 8 4 ...

Page 6: ...nsor Connections Remote ORP Connections 2b Cell and Manifold Installation 6 Verification of Flow Switch Protection 6 Section 3 OPERATION 3a Key Features Display Panel 7 9 3b Pool Water Preparation 10 Salt Requirement Chart Start Up Procedure s 3c Monitoring and Maintenance 11 Water Chemistry Parameters Saturation Index Section 4 SERVICE and MAINTENANCE 4a Control Box and Fuse Locations 12 Tri Sens...

Page 7: ...e 10 forsalt requirements the tri sensor assembly holes to tighten the screws RATINGS Input Power 115 VAC 3 0 AC amps MaximumOutput Equivalent to 0 88 kg 1 92 lbs of free available chlorine or bromine day 230 VAC 1 5 AC amps RC 13 Cell Power Level 3 8 amps DC 50 60 Hz Cell Life Expectancy A minimum of 15 000 ampere hours Output Power Cell Power 1 5 0 DC amps Agency Approvals NSF ETL us ETL c CE Ce...

Page 8: ...ion to the LOAD SIDE of your time clock electronic controller switch or relay to work in conjunction with your circulation pump For control of your main circulation pump single or two speed through the Lectranator Digital Model DIG60 s Internal Relay cut and strip the pre wired Line In wires and jump 1 to 3 and 2 to 4 Gr Yel can be discarded Route a new set of Pump AC Line IN wires from the circui...

Page 9: ...ollowing this procedure to verify that the flow switch is working as designed which is to halt power from being sent to the cell in the presence of insufficient flow A defective Flow Switch could cause serious personal and or equipment damage Using either a GOLF BALL or small plastic wrap saran wrap food wrap or zip lock bag block off flow to the upper portion of the manifold by placing the golf b...

Page 10: ...til the end of the cycle or when manually discontinued When Boost is activated with External Timer setting programmed the time remaining for the boost cycle is held in memory and will start up in Boost mode until expired With Pump Program or 2 Speed Pump setting programmed the time clock will be over ridden producing sanitizer until the end of the boost cycle The display will indicate the BOOST Mo...

Page 11: ...ric displays volume in gallons or cubic meters salt additions in lbs or kg Back Main Menu 2 0 2 2 Temperature Units displays the water temperature in Fahrenheit or Celsius Back Main Menu 2 0 2 3 12 24 hour Time displays the current time in 12 hour Time or 24 hour Time units Back Main Menu 2 0 2 4 Set Time of Day sets the time as follows Set Hours Set Minutes 2 5 Pump Program 1 allows you to progra...

Page 12: ...tion solution 3 8 Replace Cell Only used when replacing cells May be used to zero the amp hour counter Consult Lectranator Systems Inc for details 3 9 Back Main Menu returns to MAIN MENU 4 0 INSTALLER MENU Hold Select for 10 seconds to enter this mode Use UP DOWN ARROW and SELECT to scroll through the sub menu After completing a step it displays the next step 4 1 English Metric displays volume in ...

Page 13: ...es in the salt Ensure that ANY salt you use contains a minimum purity of 99 Sodium Chloride NaCl NOTE Do not use Rock Salt due to its high levels of impurities TEST YOUR WATER FOR SALT LEVEL FIRST with the provided salt test strips and then use the chart below to determine the amount of salt to add SALT REQUIREMENT CHART KILOS LBS OF SALT NEEDED FOR 3000 PPM RESIDUAL SALT Level Before Addition Poo...

Page 14: ...cid levels at the same time as your salt level as these tend to deplete at the same rate Regulations may exist regarding the use of cyanuric acid please consult your local authority NOTE For Bromine or indoor pools it is not necessary to add stabilizer SALT RESIDUAL Your Lectranator Digital Model DIG60 works most efficiently with salt levels between 2 8 3 2 gm l 2800 3200 ppm If it falls below 2 8...

Page 15: ... electrical connections and fuses Fuse Location and Ratings F1 Main AC Power Fuse 6 Amps 250 VAC F2 F3 Control Panel Circuit Board Fuse Cell Fuse 3 Amps 250 VAC 10 Amps 250 VAC TRI SENSOR ASSEMBLY The Tri sensor assembly tests for Flow Salt and Water temperatures A minimum flow rate of 94 5 L min 25 US Gallons min is required to activate the flow switch As the water flow closes the paddle a magnet...

Page 16: ...be treated with a mixture of one 1 part Muriatic Acid into four 4 parts water Mix the solution in a container high enough to cover the Cell blades You may also use TABEX LectraClean non fuming pre mixed cell cleaner per label directions Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes An effervescences action indicates the cal...

Page 17: ...lytic Cell Cell Unions and Cord ordered separately 12 ft 3 6m Cell Cord 952 1 Union O Ring 19013 Nut Half only 2 pcs for 2 in 50 mm S x S Union Thread Half Only for 2 in 50 mm S x S Union Tri Sensor Assembly Cord Ordered Separately DirectionalFlowIndicator View of locking Quick connect heads 12 ft 3 6m Tri Sensor Cord 956 DIG Tri Sensor O Ring 19028 Temperature Sensor Post Salt Sensor Blades Flow ...

Page 18: ... and corrosion 4 Premature Cell Failure Requires Replacement Cell A Abnormally high Cell usage due to an insufficient A Check the stabilizer level and adjust to recommended levels Stabilizer Cyanuric acid level B ExcessiveScale DebrisintheCell B See Section 2 above C Cell Type selection not matched to the Cell installed C Follow the INSTALLER SETUP instructions see page 8 5 White Flakes in the Wat...

Page 19: ......

Reviews: