 Maintenance

Changing the Internal Light

1.  Before carrying out the bulb replacement always 

adjust the thermostat control dial to Position 0, then 
disconnect the mains supply.

2.  While holding the lamp cover place coin between lamp 

cover lip and internal wall of the refrigerator and twist 
the coin.

3.  Remove the lamp cover.
4.  Remove the old bulb by unscrewing in an anti-clockwise direction.
5.  Replace with a new bulb (220~240V, max. 15W). Please make sure that it is secure in the bulb 

cover.

6.  Refit the light bulb cover and reconnect the unit to the mains supply and switch on.

Care When Handling / Moving Your Unit

Hold the unit around its sides or base when moving it. Under no circumstances should it be 
lifted by holding the edges of the top surface.

Servicing

The unit should be serviced by an authorised engineer and only genuine spare parts should be 
used. Under no circumstances should you attempt to repair the unit yourself. Repairs carried 
out by inexperienced persons may cause injury or serious malfunction. Contact a qualified 
technician.

When the unit is not in use for a long period of time, disconnect it from the mains supply, empty 
all food and clean the appliance, leaving the door ajar to prevent unpleasant smells.

Condensation

Condensation may appear on the outside of the unit. This may be due to a change in room 
temperature. Wipe off any moisture residue. If the problem continues, please contact a qualified 
technician for assistance.

 Disposal

Old units still have some residual value. An environmentally friendly method of disposal will 
ensure that valuable raw materials can be recovered and used again. The refrigerant used in 
your unit and insulation materials require special disposal procedures. Ensure that none of the 
pipes on the back of the unit are damaged prior to disposal.
Up to date information concerning options of disposing of your old unit and packaging from 
the new one can be obtained from your local council office.
When disposing of an old unit break off any old locks or latches and remove the door as a 
safeguard.

1

2

Summary of Contents for L5017B

Page 1: ...L5017W S B...

Page 2: ...Your Unit 10 Product Overview 11 Operation 12 Switching On Your Unit 12 Adjusting the Temperature 12 Noises Inside the Unit 12 Tips for Keeping Food in the Unit 13 Cleaning 13 Defrosting 13 Cleaning...

Page 3: ...the plug is easily accessible to enable disconnection from the mains supply If the mains cable is damaged it must be replaced by the manufacturer Choose a location for your unit away from heat sources...

Page 4: ...the food storage compartments of the unit unless they are of the type recommended by the manufacturer Do not damage the refrigerant circuit The refrigerant is a very environmental friendly gas but is...

Page 5: ...for details The Main Unit Salad Bin Adjustable Glass Shelf x 2 Salad Bin Cover Door Shelf x 2 Lower Door Shelf Egg Tray Thank youfor purchasing your new LEC Undercounter Fridge We recommend that you s...

Page 6: ...s unit is not designed for use in a garage or an outbuilding Do not drape the unit with any covering Levelling the Unit To do this adjust the two levelling feet at the front of the unit If the unit is...

Page 7: ...this may damage the coolant system We recommend that 2 people handle the unit during assembly If you want to have the door swing reversed we recommend that you contact a qualified technician You shou...

Page 8: ...the corresponding position on the opposite side of the unit bottom 4 Swap the bottom bush and bottom bush cap of the upper door The bottom bush key must be in the correct position to allow it to be in...

Page 9: ...so that the seals are closed on all sides before finally tightening the top hinge Insert the hinge bracket and screw it to the top of the unit 9 Use a spanner to tighten it if necessary 11 With the d...

Page 10: ...a damp cloth If you require more information refer to the Cleaning section Before Plugging in YOU MUST Check that you have a socket which is compatible with the plug supplied with the unit Before Tur...

Page 11: ...11 Product Overview Adjustable GlassShelves Salad Bin Cover Salad Bin Internal Light and Thermostat Control Dial Lower Door Shelf Levelling Feet Upper Door Shelf Egg Tray...

Page 12: ...eck the temperature you will need a special fridge freezer thermometer These are available from most supermarkets and hardware shops Place the thermometer in the centre of the unit where it can be rea...

Page 13: ...or is closed to avoid the polish getting on the magnetic door seal or inside the unit The grille of the condenser at the back of the unit and the adjacent components can be vacuumed using a soft brush...

Page 14: ...f Repairs carried out by inexperienced persons may cause injury or serious malfunction Contact a qualified technician When the unit is not in use for a long period of time disconnect it from the mains...

Page 15: ...annum based on standard test results for 24 hours Actual energy consumption will depend on how the appliance is used and where it is located Storage volume cooling compartment l 110 Storage volume fre...

Page 16: ......

Page 17: ...0344 8153737...

Reviews: