Working logic 

 

“Step-by-Step” logic (Dip 1 = OFF   Dip 2 = ON)

 

Start 

control puts into motion, a following control stops the motion, a further 

Start

 control reverses the motion (direction reverse).

          

 

 

“Automatic closing” (Dip 1 = ON   Dip 2 = ON) 

When the gate has reached opening it will automatically close after the set 

Pause  time

. A 

Start

 control supplied during the pause interrupts work 

cycle and the gate doesn’t close automatically. 

Photocell 

intervention during pause time reloads it, extending the period before automatic closing. 

 

“Condominium” logic (Dip 1 = not influent   Dip 2 = OFF   Dip 3 = not influent) 

When  the  gate  has  reached  opening  it  will  automatically  close  after  the  set 

Pause  time

.  A 

Start 

control  supplied  while  opening  is  not  influent.        

Start 

control supplied while closing provokes the stop and gear reverse after approx. 

1,5  sec

.. A 

Start 

control or 

Photocell

 intervention during 

pause time reloads it, extending the period before automatic closing. 

 

WARNING: 

after each modification of the working logic, switch the control unit off and on again to make the change active. 

 

“Immediate closing” (DP3=ON    DP2=ON) 

In opening phase and during pause time, after having passed the 

Photocell

, it determines the stop and, after 

1,5 sec

., gate closing. 

 

Programming 

 

Learning of remote controls  

To enter a 

Start

 code, press the 

P1

 key once. To enter a 

Pedestrian  start 

code, press the 

P1

 key twice. Each time the 

P1

 key is pressed, the 

DL1

 led 

emits a short flash. After 

3  seconds 

from the last pressure of 

P1

, the 

DL1

 led turns on with a steady light. Then press the key to be memorized on the 

remote  control.  The 

DL1

  led  will  switch  off,  indicating  that  the  code  has  been  memorized.  If  the  code  is  not  recognized,  the 

DL1

  led  stays  on  for         

10 sec., after which it will automatically switch off

.  

 

Erasing of all memorized codes 

To delete all the stored codes, keep the 

P1 

key pressed for approx. 

10 sec. 

until the 

DL1 

led turns off. 

 

Setting of pause time  

To  set  the 

pause  time

,  press  the 

P2 

key  once. 

DL1 

led  emits  a  short  flash  and,  after 

3  sec

.,  turns  on  with  a  steady  light.  Let  pass  the  time         

corresponding to the desired time and press again the key 

P2

 

Programming of work time  

Make sure the gate is completely opened. Press button 

P3

 for approx. 

3  sec.

 until 

DL1

 led  turns on with steady light and the gate start to close.  

Wait  for  the  gate  to  reach  the 

closing  limit  switch

.  The  gate  stops  and  the  Led 

DL1

  switches  off,  signalling  the  end  of  the  programming.          

The  program  automatically  computes  the  point  of  slowing  down  start  (

1/8  of  stroke

).  To  modify  it,  while  programming  press  the  key 

P3

  in  the 

wished point during closing step. 

 

Technical data

 

Card dimensions and weight

: 170 x 70 x 45 mm – 0,14 Kg 

Card power supply (Vin)

: 20

 

Vac  

Stand-by power consumption

: approx. 1

 

Operating temperature range

:  0  to + 60 °C 

Brushless motor power supply

: 24

 

Vdc 

Blinker power supply (LED)

: 12

 

V  3

 

W max. 

Accessories power supply

: 12

  

Vdc  3

 

W max. 

Pause time regulation

: 1  to 300 sec.  % 

 

DECLARATION OF CONFORMITY  

 

 

Device description:  

Electronic board controlling a 24

 

Vdc Brushless motor destined to sliding gate automation. 

 

Model:     

CTR640 

 

Applied rules:    

EN 61000-6-3, EN 61000-6-1, EN 301489-1, EN 301489-3, EN 300220-2, EN 300220-1, EN 60950-1 

 

Test laboratory:    

NEMKO SPA 

 

 

The manufacturer declares that above mentioned products comply with rules required by European directives  

2004/108/EC 

and 

2006/95/EC

 

Date: 15-07-2020 

CONNECTIONS

 

Receiver 

DS1 

DS1 

 1 

 

2   3 

ON 

OFF 

Summary of Contents for CTR640

Page 1: ... la condizione anomala Non appena l ostacolo è rimosso ha inizio il ciclo di lavoro Lampeggiatore LAMP Lampada che ha lo scopo di segnalare otticamente la condizione di pericolo determinata dal cancello in movimento Le logiche di lampeggio sono le seguenti Lampeggio veloce 2 lampeggi sec segnala la fase di apertura Lampeggio lento 1 lampeggio sec segnala la fase di chiusura Luce fissa segnala che ...

Page 2: ...emorizzare sul radiocomando Il led DL1 si spegnerà segnalando che il codice è stato memorizzato In caso di mancato riconoscimento del codice il led DL1 rimane acceso per 10 sec dopodiché si spegnerà automaticamente Cancellazione codici radiocomando Per cancellare tutti i codici tenere premuto il tasto P1 per circa 10 sec fino allo spegnimento del led DL1 Impostazione tempo di pausa Per impostare i...

Page 3: ...on as the obstacle is removed work cycle starts Blinker LAMP Card gives a command on off blink to a lamp intended to signal danger situation caused by moving gate Blinking logics are the following ones Fast blinking 2 blinks sec signals opening step Slow blinking 1 blink sec signals closing step Fixed light signals that the gate is stopped waiting the obstacle obscuring the photocell photostop or ...

Page 4: ...ed will switch off indicating that the code has been memorized If the code is not recognized the DL1 led stays on for 10 sec after which it will automatically switch off Erasing of all memorized codes To delete all the stored codes keep the P1 key pressed for approx 10 sec until the DL1 led turns off Setting of pause time To set the pause time press the P2 key once DL1 led emits a short flash and ...

Page 5: ... commence Clignotant LAMP La carte donne une commande on off clignotement à une lampe qui a le but de signaler la condition de danger déterminée par le portail en mouvement Les logique de clignotement sont les suivantes Clignotement rapide 2 clignotements sec signale la phase d ouverture Clignotement lent 1 clignotement sec signale la phase de fermeture Lumière fixe signale que le portail est arrê...

Page 6: ...fixe Ensuite appuyer sur le bouton de la radiocommande qui doit être mémorisé Le led DL1 s éteindra en signalant que le code a été mémorisé En cas de reconnaissance du code manquée le led DL1 reste allumé pendant 10 sec après il s éteindra automatiquement Effacement de tous les codes de la mémoire Maintenir pressée le bouton P1 pendant 10 sec jusqu à quand le led DL1 s éteindre Programmation temps...

Reviews: